Logbox-LTE 4G Datalogger
Multichannel IoT Datalogger.
LogBox LTE is a multichannel IoT data logger that operates on the NB-IoT and Cat-M1 bands, allowing for continuous monitoring of remote applications practically and securely. The measured data is stored in the device's internal memory and published periodically to other cloud systems.
LogBox LTE is a multichannel IoT data logger that operates on the NB-IoT and Cat-M1 bands, allowing for continuous monitoring of remote applications practically and securely. The measured data is stored in the device's internal memory and published periodically to other cloud systems.
The LogBox LTE has two universal analog inputs, 0 to 10 Vdc or 4 20 mA, and one digital input that can operate as a pulse counter (flow sensors) or event recorder (door opening/closing). It also has a digital output that can be remotely activated via SMS or MQTT command, as it operates in the "publisher" and "subscriber" modes.
The LogBox LTE uses the NXperience software, which has the NXperience Trust version, meeting the technical requirements of the FDA 21 CFR Part 11 for computer system validation and GMP (Good Manufacturing Practice).
The NOD-011A uses the IoT network CAT-M1 (LTE-M) or NB-IoT instead of the traditional LTE network. Therefore you may want to consider getting a dedicated SIM card from one of the following service providers:
- https://1nce.com/en-ap/ (Ocean Controls has successfully tested)
- Telstra: https://www.telstra.com.au/small-business/internet-of-things/data-sim-plans#standalone
- https://m2mone.com.au/sims/nb/
You can check the coverage map from Telstra and Optus here:
- Telstra (LTE-M and NB-IoT): https://www.telstra.com.au/business-enterprise/about-enterprise/our-network/iot-coverage-map
- Optus (NB-IoT): https://www.optus.com.au/living-network/coverage
- Power supply: 10 to 30 VCC
- Input Signals:
- 1 Digital Input
- 2 Analog Inputs
- Analog signal type:
- Thermocouples J,K,T,N,E,R,S and B
- Pt100, 0-50mV, 0-5V, 0-10V, 0-20mA, 4-20mA
- Digital Input Functions: Count Pulses, Register Events or Start Logger
- Digital Output: 1 PNP Output (Electronic Key or Alarm)
- Internal sensors: NTC for temperature, Battery Voltage and External Source Voltage.
- Display: 3 lines with 4½ digits
- Resolution:
- Analog channels: 15 bits
- Pulse counter: 16 bits
- Memory Capacity: 140,000 records
- Recording Interval: 1sec to 12h
- Variable Record: Instantaneous or average
- Acquisition Trigger: Date/Time, Start button, Digital Input or by software.
- Alarms:
- 8 Alarms (two per channel)
- Minimum and maximum
- Internal Buzzer: Yes
- Communication Interfaces:
- Mobile communication (NB-IoT, Cat-M)
- USB
- Configuration software: NXperience for Windows and NXperience Mobile app
- Communication with SCADA or Cloud system: MQTT Protocols
- Backup battery:
- 1 alkaline battery
- Operating Temperature:
- With source: -20 to 60°C
- Housing Protection: IP40
- Dimensions: 120 x 100 x 40 mm
Faulty Goods and Warranty
Where such goods have been supplied we undertake to repair or replace them as quickly as possible.Prior to returning faulty items, please contact us with a description of the fault as one of our engineers might be able to assist you by resolving the issue over the phone.
A Warranty form must be filled out and returned with any goods.
Our standard warranty period is 12 months from the date of purchase unless stated otherwise.
Other warranty periods:
Labjack Products: 5 Years
Atop Products: 3 Years
MeanWell Products: 3 Years
Terracom Products: 3 Years
Warranty is subject to us being satisfied that a defect was caused by defective workmanship or materials and was not caused by or was not substantially contributed to by other factors beyond our control including incorrect installation, alterations or modifications of the product not recommended by the manufacturer.
Returns Policy
If you are dissatisfied with our goods you may return them within 14 days of the dispatch date. Contact us for an authorisation and we will refund your purchase less shipping costs and restocking fees. All returned goods MUST be in AS NEW condition including ALL PACKAGING and DOCUMENTATION / MANUALS etc.
Please note:
- The product returned will attract a 20% restocking fee.
- The customer must pay the delivery costs.
- Non standard, custom made or a specially manufactured or imported products are not returnable.
- Semiconductors, books and software are not refundable
Full Terms and Conditions
By placing an order with Ocean Controls, you agree to be bound by our Terms and Conditions of Trade.