M60-LC Load Cell Indicator, 24 VDC Powered
Load cells of 1mV/V, 2mV/V and 3 mV/V, and signal ranges up to 100mV. Provides excitation voltage configurable to +5 Vdc or +10 Vdc (max. 140mA) to power up to 8 standard 350 Ohms cells. Scalable reading from 999999 to -199999 with configurable decimal point.
Fema Electronica's M60-LC digital panel meter, with 96 x 48 mm (1/8 DIN) size and 6 digits with 14 mm digit height, for load cell signals. Provides excitation voltage configurable to +5 Vdc or +10 Vdc to power up to 8 standard 350 Ohms cells. Scalable reading from 999999 to -199999 with configurable decimal point.
Tare function, with configurable controls, and ‘auto-tare’ function for automatic tare correction when weight is removed from the cell. Three working modes with different acquisition speeds and noise rejection to 50 and 60 Hz. Output and control options with 1, 2 and 3 relays, isolated analog outputs, Modbus RTU communications, transistor outputs, SSR control outputs, RS-485 ASCII and RS-232.
Special options up to 4 and 6 relays. Independent alarms configurable as maximum or minimum, with activation at setpoint or when reading is stable, with 1 or 2 setpoints per alarm, hysteresis, independent activation and deactivation delays, configurable inverted activation of the relay and configurable locked alarms
Features:
- Analog Output 4-20mA
- Alarm Relay Output
- Modbus RTU RS485 communications
Manufacturer Part No - M60-LC-L-S4-AO-R1
Display
- digits 6
- display 999999 / -199999
- decimal point configurable
- led color red or green
- digit height 14 mm
- digit type 7 segments
- units labeling ‘Units-8’ included (see ‘Accessories’)
Load cells
- types of load cells 1 mV/V, 2 mV/V, 3 mV/V and others
- excitation voltage 5 Vdc o 10 Vdc configurable
- maximum exc. current 140 mA
- maximum Vdc at input ±30 Vdc
- number of wires 4 and 6 wire cells
- number of cells* 1 to 8 load cells (at 5 Vdc)
- *(for standard 350 Ohms cells) 1 to 4 load cells (at 10 Vdc)
Measurement
- signal ranges (internal) 100 mV, 30 mV, 20 mV, 15 mV, 10 mV, 5 mV
- accuracy at 25 ºC 0.05 % FS
- thermal stability 50 ppm/ºC
- input impedance 20 MOhm
- acquisitions per second 16, 50 or 60 acq. / sec. (configurable)
- display refresh 16, 50 o 60 acq. / seg. (configurable)
- step response 17, 20 or 63 mSec. (configurable)
- signal terminals plug-in screw terminals (3.81 mm pitch)
Output and control options relays, analog outputs, Modbus RTU, ...
Configuration by front keypad External contact with configurable functions
Power
- power ‘H’ 85 to 265 Vac / dc
- power ‘L’ 11 to 60 Vdc and 24 / 48 Vac (isolated 1500 Veff)
- consumption
- power terminals plug-in screw terminals (5.08 mm pitch)
- power wires max. 2.5 mm2 (max. AWG14)
Mechanical
- front protection IP65
- connections plug-in screw terminals
- weight
- mounting panel
- front size 96 x 48 mm (1/8 DIN)
- panel cut-out 92 x 44 mm
- depth 91 mm (including terminals)
Temperature operation 0 to 50 ºC, storage -20 to 70 ºC
Faulty Goods and Warranty
Where such goods have been supplied we undertake to repair or replace them as quickly as possible.Prior to returning faulty items, please contact us with a description of the fault as one of our engineers might be able to assist you by resolving the issue over the phone.
A Warranty form must be filled out and returned with any goods.
Our standard warranty period is 12 months from the date of purchase unless stated otherwise.
Other warranty periods:
Labjack Products: 5 Years
Atop Products: 3 Years
MeanWell Products: 3 Years
Terracom Products: 3 Years
Warranty is subject to us being satisfied that a defect was caused by defective workmanship or materials and was not caused by or was not substantially contributed to by other factors beyond our control including incorrect installation, alterations or modifications of the product not recommended by the manufacturer.
Returns Policy
If you are dissatisfied with our goods you may return them within 14 days of the dispatch date. Contact us for an authorisation and we will refund your purchase less shipping costs and restocking fees. All returned goods MUST be in AS NEW condition including ALL PACKAGING and DOCUMENTATION / MANUALS etc.
Please note:
- The product returned will attract a 20% restocking fee.
- The customer must pay the delivery costs.
- Non standard, custom made or a specially manufactured or imported products are not returnable.
- Semiconductors, books and software are not refundable
Full Terms and Conditions
By placing an order with Ocean Controls, you agree to be bound by our Terms and Conditions of Trade.