M60-LC Load Cell Indicator, 24 VDC Powered
Load cells of 1mV/V, 2mV/V and 3 mV/V, and signal ranges up to 100mV. Provides excitation voltage configurable to +5 Vdc or +10 Vdc (max. 140mA) to power up to 8 standard 350 Ohms cells. Scalable reading from 999999 to -199999 with configurable decimal point.
Fema Electronica's M60-LC digital panel meter, with 96 x 48 mm (1/8 DIN) size and 6 digits with 14 mm digit height, for load cell signals. Provides excitation voltage configurable to +5 Vdc or +10 Vdc to power up to 8 standard 350 Ohms cells. Scalable reading from 999999 to -199999 with configurable decimal point.
Tare function, with configurable controls, and ‘auto-tare’ function for automatic tare correction when weight is removed from the cell. Three working modes with different acquisition speeds and noise rejection to 50 and 60 Hz. Output and control options with 1, 2 and 3 relays, isolated analog outputs, Modbus RTU communications, transistor outputs, SSR control outputs, RS-485 ASCII and RS-232.
Special options up to 4 and 6 relays. Independent alarms configurable as maximum or minimum, with activation at setpoint or when reading is stable, with 1 or 2 setpoints per alarm, hysteresis, independent activation and deactivation delays, configurable inverted activation of the relay and configurable locked alarms
Features:
- Analog Output 4-20mA
- Alarm Relay Output
- Modbus RTU RS485 communications
Manufacturer Part No - M60-LC-L-S4-AO-R1
Display
- digits 6
- display 999999 / -199999
- decimal point configurable
- led color red or green
- digit height 14 mm
- digit type 7 segments
- units labeling ‘Units-8’ included (see ‘Accessories’)
Load cells
- types of load cells 1 mV/V, 2 mV/V, 3 mV/V and others
- excitation voltage 5 Vdc o 10 Vdc configurable
- maximum exc. current 140 mA
- maximum Vdc at input ±30 Vdc
- number of wires 4 and 6 wire cells
- number of cells* 1 to 8 load cells (at 5 Vdc)
- *(for standard 350 Ohms cells) 1 to 4 load cells (at 10 Vdc)
Measurement
- signal ranges (internal) 100 mV, 30 mV, 20 mV, 15 mV, 10 mV, 5 mV
- accuracy at 25 ºC 0.05 % FS
- thermal stability 50 ppm/ºC
- input impedance 20 MOhm
- acquisitions per second 16, 50 or 60 acq. / sec. (configurable)
- display refresh 16, 50 o 60 acq. / seg. (configurable)
- step response 17, 20 or 63 mSec. (configurable)
- signal terminals plug-in screw terminals (3.81 mm pitch)
Output and control options relays, analog outputs, Modbus RTU, ...
Configuration by front keypad External contact with configurable functions
Power
- power 11 to 60 Vdc and 24 / 48 Vac (isolated 1500 Veff) (optional ‘H’ 85 to 265 Vac / dc)
- consumption ≤ 1.5 W (meter only) ≤ 4.0 W (meter with output options)
- power terminals plug-in screw terminals (5.08 mm pitch)
- power wires max. 2.5 mm2 (max. AWG14)
Mechanical
- front protection IP65
- connections plug-in screw terminals
- weight ≤ 150 grams
- mounting panel
- front size 96 x 48 mm (1/8 DIN)
- panel cut-out 92 x 44 mm
- depth 91 mm (including terminals)
Temperature operation 0 to 50 ºC, storage -20 to 70 ºC
Dispatch
In-stock orders are dispatched within 2 business days.
Shipping options
We deliver across Australia and internationally by any of the following methods:
- Australia Post Express
- Australia Post Parcel Post
- DHL
- FedEx (only international)
- Freight account. We'll email packaging dimensions when the shipment is ready to be book.
*Transit times vary depending on the shipping method and destination.
Store Pickup - Carrum Downs, Victoria, 3201
Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays.
RETURNS
How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.
Return window 14 days from dispatch date.
Condition required Items must be unused and in original packaging, including all documentation and manuals.
Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.
Non-returnable items
- Custom-made or specially imported products
- Software licences (some software have trial versions available)
- Items not in original, as-new condition
WARRANTY
How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods.
What's covered Defects in materials and workmanship under normal use and correct installation.
What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.
Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.
Extended warranty
- Labjack: 5 Years
- Atop: 5 Years
- MeanWell: 3 Years
- Teracom: 3 Years
- Novus: 3 Years