Flow Rate Indicator - N1500FT 240VAC RS-485

Flow Rate Indicator - N1500FT 240VAC RS-485

SKU: IPI-106

Tailor made for flow applications, this instrument measures and displays both the instant measured value and the totalized value. One model is capable of reading a 4-20 mA signal or a pulsed signal.

NOT AVAILABLE FOR BACKORDER

Novus
  • Manufacturer: Novus
  • $319.45
Qty:  
In stock(2 items available)

Tailor made for flow applications, this instrument measures and displays both the instant measured value and the totalized value. One model is capable of reading a 4-20 mA signal or a pulsed signal. Input type is fully software selected. Several display modes are avaliable and instrument can be ordered with up to 4 relays plus digital communication. It boasts dual retransmission outputs: one 4-20 output, typically for instant flow, and the other is a pulse (NPN) output, typically for totalized flow. Both outputs are isolated.

- Inputs: 4-20 mA, NPN, PNP, dry contact or coil signal
- 4-20 mA input with integral function and square root option
- Capable of reading ppulsed signals from 0.1 to 8000 Hz
- Resetable or continuous totalization (on the same model)
- Fully customized scale factors
- Configurable input filters
- With pulsed input being used, the 4-20 mA input can be used as an auxiliary input (example: pressure reading)
- Isolated 4-20 mA output (instant flow) and pulse output (NPN - totalized)
- The outputs can be manually changed for easier setup
- Dosage monitorign functions ensure product quality and consistancy
- Display Functions for HOLD, MAX and MIN
- Dual 6-digit displays, allows for several display messaging configuration
- Customized linearization
- Fully keypad programmable with user friendly menu
- Configuration can be password protected
- Configurable alarms: HI, LO and sensor break
- Alarms: 2 SPDT 3 A/ 250 Vac relays

Manual

Tailor made for flow applications, this instrument measures and displays both the instant measured value and the totalized value. One model is capable of reading a 4-20 mA signal or a pulsed signal. Input type is fully software selected. Several display modes are avaliable and instrument can be ordered with up to 4 relays plus digital communication. It boasts dual retransmission outputs: one 4-20 output, typically for instant flow, and the other is a pulse (NPN) output, typically for totalized flow. Both outputs are isolated.

- Inputs: 4-20 mA, NPN, PNP, dry contact or coil signal
- 4-20 mA input with integral function and square root option
- Capable of reading ppulsed signals from 0.1 to 8000 Hz
- Resetable or continuous totalization (on the same model)
- Fully customized scale factors
- Configurable input filters
- With pulsed input being used, the 4-20 mA input can be used as an auxiliary input (example: pressure reading)
- Isolated 4-20 mA output (instant flow) and pulse output (NPN - totalized)
- The outputs can be manually changed for easier setup
- Dosage monitorign functions ensure product quality and consistancy
- Display Functions for HOLD, MAX and MIN
- Dual 6-digit displays, allows for several display messaging configuration
- Customized linearization
- Fully keypad programmable with user friendly menu
- Configuration can be password protected
- Configurable alarms: HI, LO and sensor break
- Alarms: 2 SPDT 3 A/ 250 Vac relays

Manual

    • SKU
      IPI-106
    • Weight
      0.35 kg
    • Dimensions (L x W x H)
      13 x 10 x 7 cm

Faulty Goods and Warranty

Where such goods have been supplied we undertake to repair or replace them as quickly as possible.Prior to returning faulty items, please contact us with a description of the fault as one of our engineers might be able to assist you by resolving the issue over the phone.
A Warranty form must be filled out and returned with any goods.

Our standard warranty period is 12 months from the date of purchase unless stated otherwise.

Other warranty periods:

Labjack Products: 5 Years
Atop Products: 3 Years
MeanWell Products: 3 Years
Terracom Products: 3 Years

Warranty is subject to us being satisfied that a defect was caused by defective workmanship or materials and was not caused by or was not substantially contributed to by other factors beyond our control including incorrect installation, alterations or modifications of the product not recommended by the manufacturer.

Returns Policy

If you are dissatisfied with our goods you may return them within 14 days of the dispatch date. Contact us for an authorisation and we will refund your purchase less shipping costs and restocking fees. All returned goods MUST be in AS NEW condition including ALL PACKAGING and DOCUMENTATION / MANUALS etc.

Please note:

  • The product returned will attract a 20% restocking fee.
  • The customer must pay the delivery costs.
  • Non standard, custom made or a specially manufactured or imported products are not returnable.
  • Semiconductors, books and software are not refundable

Full Terms and Conditions

By placing an order with Ocean Controls, you agree to be bound by our Terms and Conditions of Trade.

Related products

Customers who viewed this product also bought