ModbusView TCP Software
ModbusView TCP software for simulating Modbus ASCII, RTU, and TCP masters and slaves.
The license takes a day or 2 to be emailed to you.
ModbusView TCP is an easy to use program that monitors and simulates Modbus ASCII, RTU and TCP/IP communications on your PC. It enables your PC to act as both a Modbus master and a slave device making it easy for you to simulate the action of your HMI machine, instruments, PLCs etc. ModbusView TCP can be downloaded below and will operate in a 15-minute trial mode. Once purchased, you will be emailed with a serial number to enable unlimited use.
Download a copy of the unregistered program from this site. The unregistered version of ModbusView TCP has all the features of the registered version except there is a time limit of 15 minutes. After 15 minutes you have to restart the program. This will allow you to trial the program before buying.
About Modbus:
Modbus is an industrial control protocol run over serial or Ethernet networks. Many PLCs, panel meters, PID controllers, HMIs, IO modules and pieces of industrial equipment can speak Modbus. ModbusView TCP allows you to interrogate and control these devices from your computer.
The Modbus master establishes a connection with the slave. The slave waits for an incoming command from the master and responds appropriately. ModbusView TCP can act as either a Modbus master or slave.
The slave can have 4 different types of internal variables that can be accessed by the master.
- Coils which are digital bits that can be read and written to. They are numbered from 00001 to 09999
- Input Status which are digital bits that can be read. They are numbered from 10001 to 19999
- Input Registers which are 16 bit integers that can be read. They are numbered from 30001 to 39999
- Holding Registers which are 16 bit integers that can be read and written to. They are numbered from 40001 to 49999
Each type in the Modbus specification can have up to 9,999 variables. The protocol can be extended to represent up to 65,536 variables using full 16 bit addressing. ModbusView TCP allows both specification-compliant and full 16 bit addressing.
The Modbus protocol has a number of different functions, some of which are specific to certain Modicon controllers and some of which are rarely used. ModbusView TCP sends and responds to a wide range of the most common Modbus commands including:
- Function 1: Read Coil Status
- Function 2: Read Input Status
- Function 3: Read Input Registers
- Function 4: Read Holding Registers
- Function 5: Write to a Coil
- Function 6: Write to a Holding Registers
- Function 15: Write to Multiple Coils
- Function 16: Write to Multiple Holding Registers
For a more detailed explanation of the Modbus protocol family visit the Web Site www.modbus.org.
- Protocols: Speaks Modbus RTU, ASCII and TCP protocols
- Run as a Modbus master or as five consecutive slave devices
- Displays and edits Holding Registers, Coils, Input Registers and Input Statuses
- Registers can be edited and shown in a wide variety of formats:
- 16 bit signed or unsigned decimal
- 32 bit decimal, little end register or big end register
- 16 or 32 bit hexadecimal, little end register or big end register
- 32 bit floating point, little end register or big end register
- "Pages" feature allows you to set up and easily switch between views of blocks of registers
- Log and Monitor views to inspect data streams
- Full 16 bit addressing of registers
Dispatch
In-stock orders are dispatched within 2 business days.
Shipping options
We deliver across Australia and internationally by any of the following methods:
- Australia Post Express
- Australia Post Parcel Post
- DHL
- FedEx (only international)
- Freight account. We'll email packaging dimensions when the shipment is ready to be book.
*Transit times vary depending on the shipping method and destination.
Store Pickup - Carrum Downs, Victoria, 3201
Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays.
RETURNS
How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.
Return window 14 days from dispatch date.
Condition required Items must be unused and in original packaging, including all documentation and manuals.
Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.
Non-returnable items
- Custom-made or specially imported products
- Software licences (some software have trial versions available)
- Items not in original, as-new condition
WARRANTY
How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods.
What's covered Defects in materials and workmanship under normal use and correct installation.
What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.
Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.
Extended warranty
- Labjack: 5 Years
- Atop: 5 Years
- MeanWell: 3 Years
- Teracom: 3 Years
- Novus: 3 Years













