FieldLogger Data Logger 512k Memory 24VDC/AC - Ethernet

FieldLogger Data Logger 512k Memory 24VDC/AC - Ethernet

SKU: NOD-002

A fully featured data logger has 8 universal inputs and can connect to Modbus slave devices for many more. USB, RS-485 and Ethernet interfaces. Web Server, FTP server, email facility, and SNMP facilities. Internal 512k memory can be augmented with a USB key or SD memory card. 

  • Master/Slave data logger
  • 24 VDC/AC Power.
Novus
  • Manufacturer: Novus
Buy more for less:
1-4items$1744.96/ each 
5-9items$1570.47/ eachsave10%
10or more items$1483.22/ eachsave15%
  • $1744.96
Qty:  
In stock(2 items available)

The new FieldLogger from Novus is a versatile, powerful and yet cost effective data logger handling analog, digital and other types of variables with high resolution and speed. It features high performance and high speed connectivity and yet is easy to configure and operate.

FieldLogger has one USB interface to be connected to a computer (for configuration, monitoring and data download) and another USB port for plugging a flash driver for data retrieval. The 512k logging basic memory is used to store data and it can be greatly expanded with an SD card.

An optional color HMI can be attached or remotely installed for local indication or configuration. A user friendly configurator software can be accessed by Ethernet, USB or RS-485 and also provides means for on-line monitoring, logged data downloading and exporting to spread sheets and other formats.

Power supply: 24 VDC/VAC

Output: 24 VDC for powering up to eight 4 to 20 mA transmitters

Universal analog input channels: 8 (Thermocouples,V, mV, mA, Pt100 and Pt1000)

Accuracy:

  • Thermocouples J, K, T, E and N: 0.2 % of the span ± 1 °C
  • Thermocouples R, S and B: 0.2 % of the span ± 3 °C
  • Pt100, Pt1000, 0-20 mA, 4-20 mA, 0-20 mV, 0-50 mV, 0-60 mV, - 20-20 mV, 0-5 V and 0-10 V: 0.15 % of the span.

Digital I/Os: 8 (individually configured as input or output)

Digital inputs:

  • Logic level 0: from 0 to 0.8 Vdc 
  • Logic level 1: from 2 to 30 Vdc 
  • Maximum input voltage: 30 Vdc 
  • Input current at 30 Vdc (typical): 3 mA

Digital output: 

  • Maximum output voltage: 30 Vdc 
  • Maximum output current: 200 mA

Relay output: 2 (NO, NC and common)

Reading and logging rates: Up to 1000/second

A/D conversion resolution: 24 bit

Memory: 512K

Alarm: Up to 32 configurable alarms. 

Maximum TCP simultaneous connections: 10 

Maximum UDP simultaneous connections: 10

Communication interface: RS485 interface (Modbus master or slave) 

  • When acting as a master, can read up to 64 registers from other slaves
  • Registers read can be used in logging, alarms or mathematical operations

Up to 128 virtual channels: 

  • Basic mathematical functions to be applied on other channels: sum, subtraction, multiplication, division, logic (AND, OR and exclusive OR), square root and power

Protection: IP20

Operating temperature: 0 to 50 °C 

Relative humidity: 80 % up to 30 °C (For temperatures higher than 30 °C, decrease 3% for °C )

    • SKU
      NOD-002
    • Weight
      0.59 kg
    • Dimensions (L x W x H)
      18.5 x 13 x 8.5 cm

Dispatch

In-stock orders are dispatched within 2 business days.

Shipping options

We deliver across Australia and internationally by any of the following methods: 

  • Australia Post Express
  • Australia Post Parcel Post
  • DHL
  • FedEx (only international)
  • Freight account. We'll email packaging dimensions when the shipment is ready to be book.

*Transit times vary depending on the shipping method and destination.

Store Pickup - Carrum Downs, Victoria, 3201

Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays. 

RETURNS

How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.

Return window 14 days from dispatch date.

Condition required Items must be unused and in original packaging, including all documentation and manuals.

Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.

Non-returnable items

  • Custom-made or specially imported products
  • Software licences (some software have trial versions available)
  • Items not in original, as-new condition


WARRANTY

How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods. 

What's covered Defects in materials and workmanship under normal use and correct installation.

What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.

Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.

Extended warranty 

  • Labjack: 5 Years
  • Atop: 5 Years
  • MeanWell: 3 Years
  • Teracom: 3 Years
  • Novus: 3 Years


Related products