Flow Rate & Totalization Panel Meter - N1500FT - 240VAC RS-485 4-Realay Output
Designed specifically for flow applications, the N1500-FT Flow Rate & Totalization Panel Meter displays both instantaneous and totalized measurements. A single model can accept either a 4–20 mA input or a pulse signal, with the input type selected entirely through software. The meter offers multiple display modes and can be configured with up to four relays and digital communication. It also includes two isolated retransmission outputs: a 4–20 mA output typically used for instantaneous flow and an NPN pulse output commonly used for totalized flow.
Tailor-made for flow applications, the Flow Rate & Totalization Panel Meter N1500-FT measures and displays both the instant measured value and the totalized value. One model is capable of reading a 4-20 mA signal or a pulsed signal. Input type is fully software-selected. Several display modes are available, and the instrument can be ordered with up to 4 relays plus digital communication. It boasts dual retransmission outputs: one 4-20 output, typically for instant flow, and the other is a pulse (NPN) output, typically for totalized flow. Both outputs are isolated.
Ideal for water and other liquid distribution systems, the N1500-FT is a flow indicator specifically designed for control and precision. It provides flexibility in measuring and displaying both instantaneous and totalized flow rate, and also offers up to four outputs that accept custom configurations, such as alarm and dosage control.
A flow indicator output can be used to switch on the start of dosing and off when the desired volume is reached. It is compatible with flow sensors with pulse, dry contact, magnetic pick-up, or 4-20mA outputs. As a differential, the 4-20mA input can also be used to indicate a second variable of choice, allowing, for example, the simultaneous indication of flow rate and pressure.
- Power: 240 Vac
- Inputs: 4-20 mA, NPN, PNP, dry contact or coil signal
- 4-20 mA input with integral function and square root option
- Capable of reading pulsed signals from 0.1 to 8000 Hz
- Resettable or continuous totalization (on the same model)
- Fully customized scale factors
- Configurable input filters
- With pulsed input being used, the 4-20 mA input can be used as an auxiliary input (example: pressure reading)
- Isolated 4-20 mA output (instant flow) and pulse output (NPN - totalized)
- The outputs can be manually changed for easier setup
- Dosage monitoring functions ensure product quality and consistency
- Display Functions for HOLD, MAX, and MIN
- Dual 6-digit displays, allows for several display messaging configuration
- Customized linearization
- Fully keypad programmable with user user-friendly menu
- Configuration can be password-protected
- Configurable alarms: HI, LO, and sensor break
- Outputs: Four Relays
- 2 SPDT 3 A/ 250 Vac relays
- 2 SPST 1.5 A / 250 Vac relays
- Communication: RS-485/Modbus RTU serial communication
- Front Panel: IP65; Polycarbonate (PC) UL94 V-2
- Enclosure: IP20; ABS + PC UL94 V-0
Dispatch
In-stock orders are dispatched within 2 business days.
Shipping options
We deliver across Australia and internationally by any of the following methods:
- Australia Post Express
- Australia Post Parcel Post
- DHL
- FedEx (only international)
- Freight account. We'll email packaging dimensions when the shipment is ready to be book.
*Transit times vary depending on the shipping method and destination.
Store Pickup - Carrum Downs, Victoria, 3201
Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays.
RETURNS
How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.
Return window 14 days from dispatch date.
Condition required Items must be unused and in original packaging, including all documentation and manuals.
Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.
Non-returnable items
- Custom-made or specially imported products
- Software licences (some software have trial versions available)
- Items not in original, as-new condition
WARRANTY
How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods.
What's covered Defects in materials and workmanship under normal use and correct installation.
What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.
Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.
Extended warranty
- Labjack: 5 Years
- Atop: 5 Years
- MeanWell: 3 Years
- Teracom: 3 Years
- Novus: 3 Years