IP67 Current/Voltage Input 4 Digit Process Indicator

IP67 Current/Voltage Input 4 Digit Process Indicator

SKU: SII-102

The Simex SRP-N118  is a 4 Digit Process Indicator which accepts 4-20mA, 0-5V or 0-10V DC input signals. It comes with  2 Relays for alarms or control and RS485 communications. DC 19~50V powered.

Simex
  • Manufacturer: Simex
Buy more for less:
1-4items$183.45/ each 
5-9items$165.11/ eachsave10%
10or more items$155.94/ eachsave15%
  • $183.45
Qty:  
In stock(1 item available)

The SRP-N118(6) meter is designed for measuring of typical current or voltage signals. The readouts are presented on well-readable display with standard range of four digits or five/six digits for more demanding applications (e.g. measurement range: 4 - 20 mA, indications range: 0 - 20 000 kg). Thanks to the tight housing with high (IP 67) protection degree, this device is particularly suitable for operations in harsh environments. 

Wide range of characteristic curves (linear, square root, quadratic, user-defined and volume characteristic for cylindrical tanks) allows the use of meters in various process control systems. The 24V DC / 100 mA output is designed to supply measuring transducers, and the RS-485 port enables data transmission in production process monitoring systems. The REL / OC control outputs can adjust the level of measured signal and are controlled according to one or two threshold values. Moreover, the meter can be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The meter may be configured with no need to open the case, by using the remote controller or with free S-Config software via the RS-485 communication port.



Features
input: 0/4-20 mA 0/1-5V, 0/2-10V
2 Relay Outputs
Modbus address selectable 01~255
Discrete screw terminals allow easy connection
CE EMC certification
Part number: SRP-N118-1821-1-3-001


The SRP-N118(6) meter is designed for measuring of typical current or voltage signals. The readouts are presented on well-readable display with standard range of four digits or five/six digits for more demanding applications (e.g. measurement range: 4 - 20 mA, indications range: 0 - 20 000 kg). Thanks to the tight housing with high (IP 67) protection degree, this device is particularly suitable for operations in harsh environments. 

Wide range of characteristic curves (linear, square root, quadratic, user-defined and volume characteristic for cylindrical tanks) allows the use of meters in various process control systems. The 24V DC / 100 mA output is designed to supply measuring transducers, and the RS-485 port enables data transmission in production process monitoring systems. The REL / OC control outputs can adjust the level of measured signal and are controlled according to one or two threshold values. Moreover, the meter can be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The meter may be configured with no need to open the case, by using the remote controller or with free S-Config software via the RS-485 communication port.



Features
input: 0/4-20 mA 0/1-5V, 0/2-10V
Modbus address selectable 01~255
Discrete screw terminals allow easy connection
CE EMC certification
Part number: SRP-N118-1821-1-3-001

Options Available
230VAC powered
6 Digits

Power supply
Power consumption
19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated
for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 5 VA; for 19V ÷ 50V DC power supply: max. 5 W
Display LED, 4 x 20 mm or 6 x 13 mm high, red (green - on request), brightness adjustable in 8 steps
Displayed values -999 ÷ 9999 or -99999 ÷ 999999 + decimal point
Input current: 0-20 mA or 4-20 mA, programmable, input resistance voltage: 0-5 V, 1-5V, 0-10V or 2-10V, programmable, input resistance > 50 kΩ
Accuracy 0.1% @25°C ± one digit
Stability 50 ppm/°C
Outputs (option) 0 or 2 x REL Imax=1A, Umax=30VDC/250VAC (cosø=1) or OC Imax=30mA, Umax=30VDC, Pmax=100mW
Analogue output - Option
(available with 1 x REL or OC,
see ordering)
active current: - range 0/4 20 mA (max. 0-24 mA), load resistance 700 Ω max., resolution 13 bit
passive current: isolated, max. 2,8-24 mA), range 4-20 mA ( load resistance 600 Ω@24VDC, resolution 13 bit
active voltage: 0/1-5V, 0/2-10V (max. 0-11V), 2000 Ω range load resistance min., resolution 13 bit
Power supply output 24V DC +5%, -10% / max. 100 mA, stabilized
Communication interface RS-485, 8N1 and 8N2, 1200 bit/s ÷ 115200 bit/s, Modbus RTU (not galvanically isolated)
Operating temp. 0°C ÷ +50°C (standard), -20°C ÷ +50°C (option)
Storage temp. -10°C ÷ +70°C (standard), -20°C ÷ +70°C (depending on option)
Protection class IP 67
Case wall mounting; material: ABS + polycarbonate (standard); 100% polycarbonate (on request)
Glands M12, cable diameter 3 ÷ 6,5 mm
Dimensions (WxHxD) without glands: 110 x 80 x 67 mm; with glands: 110 x 105 x 67 mm
Weight max. 350 g

 


    • SKU
      SII-102
    • Weight
      0.2 kg
    • Dimensions (L x W x H)
      12 x 10 x 7 cm

Faulty Goods and Warranty

Where such goods have been supplied we undertake to repair or replace them as quickly as possible.Prior to returning faulty items, please contact us with a description of the fault as one of our engineers might be able to assist you by resolving the issue over the phone.
A Warranty form must be filled out and returned with any goods.

Our standard warranty period is 12 months from the date of purchase unless stated otherwise.

Other warranty periods:

Labjack Products: 5 Years
Atop Products: 3 Years
MeanWell Products: 3 Years
Terracom Products: 3 Years

Warranty is subject to us being satisfied that a defect was caused by defective workmanship or materials and was not caused by or was not substantially contributed to by other factors beyond our control including incorrect installation, alterations or modifications of the product not recommended by the manufacturer.

Returns Policy

If you are dissatisfied with our goods you may return them within 14 days of the dispatch date. Contact us for an authorisation and we will refund your purchase less shipping costs and restocking fees. All returned goods MUST be in AS NEW condition including ALL PACKAGING and DOCUMENTATION / MANUALS etc.

Please note:

  • The product returned will attract a 20% restocking fee.
  • The customer must pay the delivery costs.
  • Non standard, custom made or a specially manufactured or imported products are not returnable.
  • Semiconductors, books and software are not refundable

Full Terms and Conditions

By placing an order with Ocean Controls, you agree to be bound by our Terms and Conditions of Trade.

Related products

Customers who viewed this product also bought