ToughSonic 100 30' - 9.1 Meter Ultrasonic Sensor (RS-485)
The ToughSonic 100 14' Range, 1.5 in NPT front and rear threads ultrasonic sensor, TS-100.30C1X.0xxFA, measures level and distance through the air using ultrasonic sound waves up to a distance of 30 feet (9.1 Meters).
These rugged, compact ultrasonic sensors live up to the “ToughSonic” name. Versatile liquid level sensors feature heavy-duty electronics that are epoxy-potted into 316 stainless steel housings.
*TS-100.30C1X.0xxFA... (1.5 in NPT front and rear threads, RS-485 Standard)
**Standard includes Analog (4- 20mA & 0- 10V or 0- 5V) Outputs, Switch Outputs, and Output Indicator.
The TS-100 features permanently attached cables and rugged piezoelectric transducers. Use the TS-100 to monitor & control water and benign liquid levels, measure distances, or detect objects.
Versatile Measurement Capabilities: Accurately measure distances, detect objects, and monitor water and benign liquid levels.
Robust Construction: Built to withstand harsh conditions, making them ideal for both indoor and outdoor use.
Wide Operating Temperature Range: Functions effectively in temperatures from -40 to +70°C.
High Ingress Protection: Rated IP68, NEMA-4X, and NEMA-6P for superior resistance against dust and water ingress.
User-Friendly Adjustments: Easily configure settings with the included SensorView software for setup, testing, and cloning sensors.
Advanced Features of TS-100 Ultrasonic Sensors
Extended Range, Minimal Dead Zone: Achieve precise distance measurements with a long-range capability and a short dead band.
Reliable in Any Environment: Unaffected by optical factors such as color, transparency, or lighting conditions.
Easy Setup & Calibration: Configure effortlessly via PC or onboard button for quick deployment.
Adjustable Sensitivity: Fine-tune detection for precise performance.
Built-in Temperature Compensation: Ensures accurate readings across a wide range of fluctuating temperatures.
Benefits of this Easy-to-Use Ultrasonic Sensor
Fast & Simple Installation: Mount with ease for quick deployment in any application.
Rugged, Sealed Housing: Designed for wet, dirty, and harsh environments.
Reliable I/O Protection: Features short-circuit and overload protection for enhanced durability.
Multi-Sensor Synchronization: Operate multiple sensors without interference.
Non-Contact: Accurately measure levels and distances without touching the material being measured.
Rear Status Indicators: Easily monitor sensor operation and diagnostics, or reset default setup using a rear push-button (N/A on TS-100.50), or the push-button can be disabled.
Common Applications for TS-100 General-Purpose Sensors
Tank Level Measurement: Accurately monitor liquid levels in tanks containing benign fluids.
Open Channel Flow Monitoring: Ideal for flow measurement in flumes, weirs, and open channels.
Roll Diameter Measurement: Precisely gauge material roll diameters for manufacturing and processing.
Loop Control & Slack Detection: Maintain optimal material tension in production lines.
Object Detection & Presence Sensing: Verify object presence or absence in designated areas.
Relative Positioning: Measure an object’s position relative to a fixed reference point for automation and alignment.
Maximum Range | 30 feet (9.1 meters) |
Optimum Range | 10 inches – 20 feet (25.4 cm- 6.1m) |
Deadband | 0-10 in (0-254 mm) |
Temperature | -40° to 158°F (-40° to 70°C) |
Humidity | 0 to 100% operating |
Protection | NEMA-4X, NEMA 6P, IP68 |
Transducer | Ruggedized piezoelectric |
Compensation | Temperature compensated (selectable in SensorView™) |
Resolution | Serial data: 0.0068 in. (0.172 mm) |
Repeatability | Nominal 0.2% of range @ constant temp. |
Update Rate | 10 Hz (100 ms), SensorView adjustable; affected by SensorView filter selections |
Outputs
Output #1 | Current sourcing 4-20 mA or SensorView adjustable, max. loop 450Ω |
Output #2 | Current sinking 4-20 mA or SensorView adjustable, max. loop 450Ω |
Voltage Output | 0-10, 0-5 VDC or SensorView customized |
4-20 mA | |
Switch Output(s) | 150 mA max. @ 40 VDC max., |
RS-232 or RS-485 | Modbus & streaming protocols |
Sync Feature |
Mechanical
Housing | 316 stainless steel |
Mounting | 30 mm threaded: |
Mounting | |
Attached Cable | 6.5 feet (2 meters), PUR jacketed |
Total Weight | 10.4 oz. (0.29 kg) |
*Specifications are subject to change without notice.
Faulty Goods and Warranty
Where such goods have been supplied we undertake to repair or replace them as quickly as possible.Prior to returning faulty items, please contact us with a description of the fault as one of our engineers might be able to assist you by resolving the issue over the phone.
A Warranty form must be filled out and returned with any goods.
Our standard warranty period is 12 months from the date of purchase unless stated otherwise.
Other warranty periods:
Labjack Products: 5 Years
Atop Products: 3 Years
MeanWell Products: 3 Years
Terracom Products: 3 Years
Warranty is subject to us being satisfied that a defect was caused by defective workmanship or materials and was not caused by or was not substantially contributed to by other factors beyond our control including incorrect installation, alterations or modifications of the product not recommended by the manufacturer.
Returns Policy
If you are dissatisfied with our goods you may return them within 14 days of the dispatch date. Contact us for an authorisation and we will refund your purchase less shipping costs and restocking fees. All returned goods MUST be in AS NEW condition including ALL PACKAGING and DOCUMENTATION / MANUALS etc.
Please note:
- The product returned will attract a 20% restocking fee.
- The customer must pay the delivery costs.
- Non standard, custom made or a specially manufactured or imported products are not returnable.
- Semiconductors, books and software are not refundable
Full Terms and Conditions
By placing an order with Ocean Controls, you agree to be bound by our Terms and Conditions of Trade.