ToughSonic 200 chemical ultrasonic sensor 14' (4.3m) PVDF housing RS-485

ToughSonic 200, Chemical Ultrasonic Sensor, 14' - 4.3 Meter (RS-485)

SKU: SNS-081

The ToughSonic 200, 14' Range, 1" NPT Upper & 1.5" NPT Lower Threads ultrasonic sensor, TS-200.14G1X.xx7FA, delivers non-contact, highly accurate liquid level measurement in chemical tanks, diesel fuel storage, and industrial liquid applications. Designed for durability, these compact and rugged sensors withstand exposure to harsh chemicals, acids, and bases

The ToughSonic 200 measures level and distance through the air using ultrasonic sound waves up to a distance of 14 ft (4.3 Meters). They are ideal for demanding paper processing, food production, and industrial storage applications. 

*TS-200.14G1X.xx7FA... (1" NPT Upper & 1.5" NPT Lower Threads, RS-485, Transistor, Current, and Voltage Outputs)

Senix
  • Manufacturer: Senix
Buy more for less:
1-4items$1399.64/ each 
5-9items$1259.67/ eachsave10%
10or more items$1189.69/ eachsave15%
  • $1399.64
Qty:  
In stock(5 items available)

ToughSonic TS-200 ultrasonic level sensors provide precise, non-contact liquid level measurement for applications such as chemical tanks, diesel fuel storage, and industrial liquids. Engineered for long-lasting performance, these compact, durable sensors resist harsh environments, including exposure to corrosive chemicals, acids, and bases, making them an excellent choice for paper processing, food production, and industrial storage systems.

Chemical-Resistant PVDF Housing: Ensures long-term performance in corrosive environments.
Non-Contact Ultrasonic Technology: Accurate level measurement without sensor contact with the liquid.
Wide Application Use: Suitable for closed or open tanks, chemical processing, and diesel fuel storage.
Extreme Durability: Rated IP68, NEMA-4X, and NEMA-6P for reliable indoor and outdoor use.
Advanced Configuration: Easily adjustable with 
SensorView software for setup, testing, and cloning sensors.
Short Nose & Deadband: Measures closer to the full tank for improved accuracy.
Versatile Mounting Options:  Features 1.5-inch and 2.0-inch BSP bottom threads and 1.0-inch NPT top threads.

TS-200: Versatile in Tough Environments

Flexible Installation Options: Top and bottom mounting threads
Ingress Protection: IP68 (submersible), NEMA-4X, NEMA-6P
Output Options: Five outputs plus serial data
Temperature Compensation: Ensures accuracy in varying conditions
PC Configurable: Adjust sensor settings easily

Measures Up to Challenging Applications

Chemical Tank Level Monitoring: Safe for use in chemical environments compatible with PVDF.
Aggressive Materials & Fuel Storage Tanks: Reliable level measurement in hostile applications.
Industrial & Factory Environments: Designed for use in the harshest conditions.
Agriculture: Liquid level monitoring in irrigation systems, ag chemicals, and livestock monitoring.
Open-Air Liquid Level Monitoring: Measures tank levels up to 14, 20, or 35 feet.

    • SKU
      SNS-0810
    • Weight
      0.87 kg
    • Dimensions (L x W x H)
      24.5 x 16 x 8.5 cm
  • Cable Length
    SNS-0810 - 2 Metres (6.5ft), SNS-0812 - 7.5 Metres (25 ft), SNS-0815 - 15 Metres (50 ft)

Dispatch

In-stock orders are dispatched within 2 business days.

Shipping options

We deliver across Australia and internationally by any of the following methods: 

  • Australia Post Express
  • Australia Post Parcel Post
  • DHL
  • FedEx (only international)
  • Freight account. We'll email packaging dimensions when the shipment is ready to be book.

*Transit times vary depending on the shipping method and destination.

Store Pickup - Carrum Downs, Victoria, 3201

Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays. 

RETURNS

How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.

Return window 14 days from dispatch date.

Condition required Items must be unused and in original packaging, including all documentation and manuals.

Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.

Non-returnable items

  • Custom-made or specially imported products
  • Software licences (some software have trial versions available)
  • Items not in original, as-new condition


WARRANTY

How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods. 

What's covered Defects in materials and workmanship under normal use and correct installation.

What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.

Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.

Extended warranty 

  • Labjack: 5 Years
  • Atop: 5 Years
  • MeanWell: 3 Years
  • Teracom: 3 Years
  • Novus: 3 Years


Maximum Range

14 feet (4.3 meters)

Optimum Range

4 in. to 10 ft (100 mm to 3 meters)

Deadband

0-12 in (0-30.5cm)

Temperature

-40° to 158°F (-40° to 70°C)

Humidity

0 to 100% operating

Protection

NEMA-4X, NEMA 6P, IP68

Transducer

Chemically isolated piezoelectric

Compensation

Temperature compensated (selectable in SensorView™)

Resolution

Serial data: 0.0034 in. (0.086 mm)
 Analog steps: 4099 (0-10 VDC),
 3279 (4-20 mA)

Repeatability

Nominal 0.2% of range @ constant temp.
 Affected by target, distance, environment

Update Rate

20 Hz (50 ms), SensorView adjustable; affected by SensorView filter selections


Outputs

Voltage Output

0-10, 0-5 VDC or SensorView customized
 10 mA maximum output current

Current Loops (x2)

Two 4-20 mA current loops:
 Current sourcing and current sinking
 Max loop resistance 450 ohms each
 SensorView customized
 Both share calibration parameters

Switches (x2)

Two switches, SensorView customized
 150 mA max @ 40 VDC max
 SensorView selected as sinking (NPN) or sourcing (PNP)
 Adjustable setpoint, polarity, hysteresis, ON and OFF timing

Serial Data Interface

Modbus & streaming protocols
 9600-115200 baud (configurable)
 8 data bits, 1 stop, no parity
 RS-485 permits multi-sensor networks
 Part number determines interface


Mechanical

Housing

Injection moulded, chemically resistant
 Polyvinylidene fluoride (PVDF)
 Also known as Kynar, a registered tradename of Arkema Inc.

Mounting

Top mount: 1-inch NPT
 Bottom: 1-1/2 in. NPT

Cable

Potted into sensor, pigtail termination
 6.5 feet (2 meters), PUR jacketed
 Custom lengths available
 Standard models: 9-wire shielded + drain
 Serial data-only models: 4-wire + drain

Total Weight

21.2 oz. (0.60 kg)
 Weight includes 6.5 ft (2 meter) cable

*Specifications are subject to change without notice.

Related products