Fema  I4L isolated signal converter for Load Cells

Fema I4L isolated signal converter for Load Cells

SKU: FMB-003

Fema I4L is an isolated signal converter for load cell signals and millivolts. Provides +5 Vdc excitation voltage to power the load cell, and ‘sense’ function to compensate for excitation voltage variations. Accepts direct connection of 1, 2, 3 or up to 4 load cells (typical 350 Ohms load cells). We have a service to configure the I4L for you if you require it.

Fema
  • Manufacturer: Fema
Buy more for less:
1-4items$211.46/ each 
5-9items$190.32/ eachsave10%
10or more items$179.74/ eachsave15%
  • $211.46
Qty:  
In stock(13 items available)

Isolated signal converter for load cell signals and millivolts. Provides +5 Vdc excitation voltage to power the load cell, and ‘sense’ function to compensate for excitation voltage variations. Accepts direct connection of 1, 2, 3 or up to 4 load cells (typical 350 Ohms load cells). Accepts 4 and 6 wire load cells. Accepts unipolar and bipolar ranges up to ±80 mV.

Output signal configurable for 4/20 mA (active or passive) and 0/10 Vdc. Universal power supply from 18 to 265 Vac/dc. 3 way isolation between input, output and power circuits. Plug-in screw terminal connections. Circuit isolation prevents ground loops and transient propagation, protecting remote equipment and signal integrity.

Two configuration modes: (1) easy and fast using predefined configuration codes, and (2) advanced configuration trough the ‘configuration menu’ to customize input and output signal ranges. Configuration through front push-button keypad and front display. ‘Tare’ function accessible from front key pad. Configurable display information (tare value, input signal value, output signal value, configured label, signal percentage, process value, excitation voltage and excitation current values). Manual ‘force’ functions to generate low and high output signals, to validate remote instrumentation during installation. ‘Password’ function to block non-authorized access to configuration menu. ‘SOS’ mode to help on critical maintenance and repairs without affecting the manufacturing process. Designed for industrial use, with potential integration into a wide range of applications, excellent quality and optional customization 

Features

  • Universal power supply 18 to 265 Vac/dc
  • 3 Way Isolation Input/Output/Power
  • 4 Digit Display showing value of input/output
  • Input Selectable
    • Load Cells 0-5mV to 0-80mV
    • Load Cells +/-5mV to +/-80mV
    • Unipolar Millivolt Signals 0-5mV to 0-80mV,
    • Bipolar Millivolt Signals +/-5mV to +/-80mV
  • Output Selectable 4-20mA and 0-10VDC
  • Configuration through front push-button keypad and front display.




Power supply:

Voltage range: 18 to 265 Vac/dc isolated (20 to 240 Vac/dc ±10%) 

AC frequency: 45 to 65 Hz 

consumption: ≤3.0 W

Input signal ranges for load cells:

 Signal ranges: from 0/5 mV up to 0/80 mV 

Bipolar signal ranges: from ±5 mV up to ±80 mV 

Excitation voltage: +5 Vdc 

Excitation voltage variations: automatic compensation 

Excitation current: max. 70 mA

Input signal ranges for millivolts:

Signal ranges: from 0/5 mV up to 0/80 mV 

Bipolar signal ranges: from ±5 mV up to ±80 mV 

Excitation voltage: no 

Input impedance: 10 MOhm typical (with 1 MOhms during 150 milliseconds, every 10 seconds approx.)

Thermal stability: 

±150 ppm/ºC (F.S.) for ranges up to 5 mV 

±100 ppm/ºC (F.S.) for ranges up to 20 mV 

±75 ppm/ºC (F.S.) for ranges up to 80 mV

Step response:

With ‘no filter’ <115 mSec. typ. (0 % to 99 % signal) 

With ‘50 Hz filter’ or ‘60 Hz filter’ <150 mSec. typ. (0 % to 99 % signal) 

With ‘50 and 60 Hz filter’ <300 mSec. typ. (0 % to 99 % signal) 

Output signal ranges:

Active current output: 4/20 mA active, max.  ≤22 mA, min. 0 mA 

Passive current output: 4/20 mA passive, max. 30 Vdc on terminals 

voltage output: 0/10 Vdc, max. ≤11 Vdc, min. -0.05 Vdc (typ.), load > 10 KOhm 

Isolation:

Input - output 3000 Veff (60 seconds) 

Power - input 3000 Veff (60 seconds) 

Power - output 3000 Veff (60 seconds)

Environmental:

IP protection: IP30 

impact protection: IK06 

Operation temperature: from 0 to +50 ºC 

Storage temperature: from -20 to +70 ºC 

‘Warm-up’ time: 15 minutes 

Humidity: 0 to 95% non condensing 

Altitude up: to 2000 meters 

    • SKU
      FMB-003
    • Weight
      0.12 kg
    • Dimensions (L x W x H)
      11 x 9 x 4 cm

Dispatch

In-stock orders are dispatched within 2 business days.

Shipping options

We deliver across Australia and internationally by any of the following methods: 

  • Australia Post Express
  • Australia Post Parcel Post
  • DHL
  • FedEx (only international)
  • Freight account. We'll email packaging dimensions when the shipment is ready to be book.

*Transit times vary depending on the shipping method and destination.

Store Pickup - Carrum Downs, Victoria, 3201

Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays. 

RETURNS

How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.

Return window 14 days from dispatch date.

Condition required Items must be unused and in original packaging, including all documentation and manuals.

Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.

Non-returnable items

  • Custom-made or specially imported products
  • Software licences (some software have trial versions available)
  • Items not in original, as-new condition


WARRANTY

How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods. 

What's covered Defects in materials and workmanship under normal use and correct installation.

What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.

Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.

Extended warranty 

  • Labjack: 5 Years
  • Atop: 5 Years
  • MeanWell: 3 Years
  • Teracom: 3 Years
  • Novus: 3 Years


Related products