Fema I4E configurable signal converters for electrical signals
The new I4E signal converters from Fema can be configured to measure voltage signals (AC and DC) with ranges from 0 / 50mV up to 0 / 600V, current signals (AC and DC) from 0 / 5mA up to 0 / 5A, and frequencies from power lines (up to 100Hz). The output is a standard process signal configurable to 4 / 20mA or 0 / 10Vdc and has 4 Digit display. We have a service to configure the I4E for you if you require it.
The Series I4 is a range of isolated signal converters, fully configurable, versatile and reliable for industrial applications. Its main features are the wide range of input signals available, and the customization that can be applied to the input and output signal ranges.
Output signal configurable for 4/20mA and 0/10Vdc, 3 way isolation between input-output-power circuits. Universal power supply 18 to 265 Vac/dc, wide range of input signals accepted, configuration through front keypad and display. Additional tools like "Force" menu to set the output to high or low value, the "SOS" mode, configurable messages on display for local monitoring of the input and output signal values, and password function to block access to configuration. For DIN rail mount.
Series I4 offers increased technical specifications in terms of accuracy and response times, allowing to integrate in a wide range of industrial control applications, data acquisition systems, and laboratory testing.
Features
- Universal power supply 18 to 265 Vac/dc
- 3 Way Isolation Input/Output/Power
- 4 Digit Display showing value of input/output
- Input Selectable
- AC Voltage 0 / 50mV up to 0 / 600V
- DC Voltage 0 / 50mV up to 0 / 600V
- AC Current 0 / 5mA up to 0 / 5A,
- DC Current 0 / 5mA up to 0 / 5A,
- Frequencies 0-100Hz
- Output Selectable 4-20mA and 0-10VDC
- Configuration through front push-button keypad and front display.
Typical Applications include measurement of electrical signals from :
- current shunts of 50mV, 60mV, 100mV, 150mV, ...
- signals from DC batteries of 12 Vdc, 24 Vdc, 48 Vdc, ...
- signals from tachometric dynamos of ±60 Vdc
- power lines of 230 Vac, 115 Vac, 48 Vac, 24 Vdc
- AC current leaks of down to 5 mAac and below
- 50 and 60 Hz frequency signals from AC power lines
- signals from X/5 and X/1 current transformers
Input signal ranges Vac:
ranges: from 0/50 mVac up to 0/600 Vac
Type of measure: True RMS
Connections accepted: phase-to-neutral
phase-to-phase
Category of measure: CAT-II up to 300 Vac
Input signal ranges Vdc:
unipolar ranges: from 0/50 mVdc up to 0/600 Vdc
bipolar ranges: from ±50 mVdc up to ±600 Vdc
Input signal ranges Aac:
ranges: from 0/5 mAac up to 0/5 Aac
type of measure: True RMS
connections accepted: phase-to-neutral
phase-to-phase
category of measure: CAT-II up to 300 Vac
Input signal ranges Adc:
unipolar ranges: from 0/5 mAdc up to 0/5 Adc
bipolar ranges: from ±5 mAdc up to ±5 Adc
Frequency AC: up to 100 Hz
Thermal stability: 150 ppm/º
Output signal ranges:
Active mA signal: 4/20 mA active, max. 22 mA, min. 0mA
Passive mA signal: 4/20 mA passive, max. 30 Vdc on terminals
Vdc signal: 0/10 Vdc, max. 11 Vdc, min. -0.1 Vdc, load > 1 KOhm
Isolation:
input - output 3000 Veff (60 seconds)
power - input 3000 Veff (60 seconds)
power - output 3000 Veff (60 seconds)
IP protection: IP30
Dispatch
In-stock orders are dispatched within 2 business days.
Shipping options
We deliver across Australia and internationally by any of the following methods:
- Australia Post Express
- Australia Post Parcel Post
- DHL
- FedEx (only international)
- Freight account. We'll email packaging dimensions when the shipment is ready to be book.
*Transit times vary depending on the shipping method and destination.
Store Pickup - Carrum Downs, Victoria, 3201
Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays.
RETURNS
How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.
Return window 14 days from dispatch date.
Condition required Items must be unused and in original packaging, including all documentation and manuals.
Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.
Non-returnable items
- Custom-made or specially imported products
- Software licences (some software have trial versions available)
- Items not in original, as-new condition
WARRANTY
How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods.
What's covered Defects in materials and workmanship under normal use and correct installation.
What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.
Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.
Extended warranty
- Labjack: 5 Years
- Atop: 5 Years
- MeanWell: 3 Years
- Teracom: 3 Years
- Novus: 3 Years