Frequency/Tachometer/Line Speed Meter with Analog Retransmission, RS-485 and 2 Relays, 230 V Powered

Frequency/Tachometer/Line Speed Meter with Analog Retransmission, RS-485 and 2 Relays, 230 V Powered

SKU: ALT-081

5 digit tachometer / line speed / frequency meter with 2 alarm relays, analog retransmission and RS-485. 100 to 240 VAC/DC powered.

DCBox
  • Manufacturer: DCBox
Buy more for less:
1-4items$346.44/ each 
5-9items$311.79/ eachsave10%
10or more items$294.47/ eachsave15%
  • $346.44
Qty:  
In stock(1 item available)

The DC5H/AM5H series are budget priced 5 digit panel meters which can be configured to operate as a tachometer, line speed meter or frequency meter. This model features 2 alarm relays, a 4 to 20 mA analog retransmission signal and a RS-485 Modbus connection.

The meter can be configured to show frequency, RPM or line speed (counting pulses from a line-following wheel or drum of configurable diameter). The unit comes with a large range of stickers for the front panel including RPM, M/min and kHz.

Line speed and RPM values can be measured using a wheel or drum sensor. The meter can be configured for sensors outputting 1 to 99,999 pulses per revolution. In line speed mode, the drum diameter can be set from 0.0001 to 9.9999 meters.

The analog output can be used to retransmit the displayed value. User-configurable high and low points allow the scaling to be changed. The polarity of the scaling can be switched for 20 to 4 mA output.

This unit has an RS-485 serial port and communicates via Modbus RTU. The displayed value can be monitored and all settings can be modified by writing to holding registers.

Manufacturer Part: AM5H-R-N2M-A-R2AY or DC5H-R-N2M-A-R2AY 

Features:

  • 5 Digit Microprocessor Rate Meter
  • Line Speed / RPM / Frequency selectable
  • Configurable Pulse per Revolution setting
  • Configurable scaling setting
  • 2 configurable alarm relays
  • Configurable low pass filter for low frequency (≤100 Hz) signals
  • CE approval
  • High stability, non-flammable case(PC), high safety

Power supply: AC/DC 100 to 240V  

Power consumption: 8.5VA (all functions output) 

Accuracy: ±0.03% F.S. 

Display screen: High brightness red LED - 20.3mm (0.8") 

Display range: 0 to 99999 

Sampling time: 

  • 10 cycles / sec: >10Hz
  • f cycles / sec: ≤10Hz

Analog output resolution: 15 bit

Output capability: 

  • Voltage output: ≤ 20mA
  • Current output: ≤ 10V

Output response time: ≤ 250 msec (0 to 90%) 

Communication: RS-485 Modbus RTU mode 

Baud rate: 38400 / 19200 / 9600 / 4800 bps 

Polarity indication: Automatic with "-" indication 

Parameters setting: Push buttons 

Back up memory: EEPROM 

Temperature coefficient: 100ppm/°C (0 to 60 °C) 

Operating temperature: 0 to 60 °C 

Operating humidity: 20 to 90% RH (non-condensing) 

Storage temperature: -10 to 70 °C 

Storage humidity: 20 to 90% RH (non-condensing) 

Dimensions: 96 × 48 × 112 mm

Input signal:

The signal input for this meter can come from a range of NPN/PNP or dry contact sensors. An external excitation voltage is supplied at the back of the unit for sensor power. As shipped from the factory, the unit is configured for 12 VDC excitation supply and NPN or dry contact input. Internal jumpers can be moved to set 5 VDC excitation or PNP input type.

A separate jumper enables a low pass filter, useful for input frequencies less than 100 Hz. By default, the unit ships with the full 100 kHz input frequency range available.

Display units and modes:

The SCALE and PPR (Pulse per Revolution) settings allow the input frequency to be scaled to just about any units desired. The meter has some functions built in that make common scaling configurations easy.

The type setting applies fixed scaling appropriate for direct frequency display (no additional scaling), RPM display (scales pulses per second to pulses per minute) and line speed, which scales pulses accounting for the diameter of a pickup wheel or drum.

  • Frequency: Displays input frequency / PPR setting × SCALE setting
  • RPM: Displays input frequency × 60 / PPR setting × SCALE setting
  • Line speed: Displays input frequency × 60 / PPR setting × SCALE setting

A second scaling setting is activated when in line speed mode. The drum or wheel diameter (set by the SCALE parameter) is configured in meters, but by setting the UNIT parameter, the display can be set to show line speed in meters/min, yard/min or feet/min.

    • SKU
      ALT-081
    • Weight
      0.41 kg
    • Dimensions (L x W x H)
      18 x 12 x 7 cm

Dispatch

In-stock orders are dispatched within 2 business days.

Shipping options

We deliver across Australia and internationally by any of the following methods: 

  • Australia Post Express
  • Australia Post Parcel Post
  • DHL
  • FedEx (only international)
  • Freight account. We'll email packaging dimensions when the shipment is ready to be book.

*Transit times vary depending on the shipping method and destination.

Store Pickup - Carrum Downs, Victoria, 3201

Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays. 

RETURNS

How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.

Return window 14 days from dispatch date.

Condition required Items must be unused and in original packaging, including all documentation and manuals.

Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.

Non-returnable items

  • Custom-made or specially imported products
  • Software licences (some software have trial versions available)
  • Items not in original, as-new condition


WARRANTY

How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods. 

What's covered Defects in materials and workmanship under normal use and correct installation.

What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.

Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.

Extended warranty 

  • Labjack: 5 Years
  • Atop: 5 Years
  • MeanWell: 3 Years
  • Teracom: 3 Years