ViewPID

Available for backorder
Free shipping
  • SKU
    OCS-007

ViewPID allows you to monitor and tune PID controllers via RS-232 or RS-485 Modbus from your computer.

  • $44.17
Qty:  

ViewPID is our new easy to use Windows PC program that monitors and records the performance of your PID controller (such as our Novus 1100, 1200, 2000 and 3000 controllers) The PC is simply connected to the PID controller with a RS-232 or RS-485 connection. The software then communicates with the Process controller using Modbus Protocol.

By connecting your PC to your PID controller using a RS-232 or RS-485 serial connection, ViewPID software interrogates your controller for the following values using Modbus protocol:

  • Process Variable
  • Setpoint
  • Output
  • Proportional Gain K
  • Integral Gain Ki
  • Differential Gain Kd

How to Download and Buy ViewPID:

Download a copy of the unregistered program from this site. The unregistered version of ViewPID has all the features of the registered version except there is a time limit of 10 minutes. After 10 minutes you have to restart the program. This will allow you to trial the program before buying. After purchasing through the website, a serial number will be emailed to you.

  • Protocol: Modbus RS-232 or RS-485
  • A trend showing the process variable, setpoint and percentage output.
  • Auto or fixed scaling on the trend
  • Able to hold the trend.
  • Able to change the period of polling from 1 to 1000 seconds
  • A display of the setpoint, gain, integral and differential parameters
  • Alter the setpoint, gain, integral and differential parameters from the display
  • Log the the process variable, setpoint and percentage output to a CSV file on your PC
  • Logged file can be opened later in Excel for analysis
  • Display a graph of your logged data.
  • Can select serial port, baud rate, parity etc

ViewPID has presets for the Novus N1020, N1100, N1200, N2000 and N3000 controllers but can be easily configured to work with other controllers by manually specifying the Modbus addresses and factors of the process variables. These can be saved to a configuration file. If you wish us to add support for your controller, please contact us and we will likely be able to add your controller in the next software update.

Faulty Goods and Warranty

Where such goods have been supplied we undertake to repair or replace them as quickly as possible.Prior to returning faulty items, please contact us with a description of the fault as one of our engineers might be able to assist you by resolving the issue over the phone.
A Warranty form must be filled out and returned with any goods.

Our standard warranty period is 12 months from the date of purchase unless stated otherwise.

Other warranty periods:

Labjack Products: 5 Years
Atop Products: 3 Years
MeanWell Products: 3 Years
Terracom Products: 3 Years

Warranty is subject to us being satisfied that a defect was caused by defective workmanship or materials and was not caused by or was not substantially contributed to by other factors beyond our control including incorrect installation, alterations or modifications of the product not recommended by the manufacturer.

Returns Policy

If you are dissatisfied with our goods you may return them within 14 days of the dispatch date. Contact us for an authorisation and we will refund your purchase less shipping costs and restocking fees. All returned goods MUST be in AS NEW condition including ALL PACKAGING and DOCUMENTATION / MANUALS etc.

Please note:

  • The product returned will attract a 20% restocking fee.
  • The customer must pay the delivery costs.
  • Non standard, custom made or a specially manufactured or imported products are not returnable.
  • Semiconductors, books and software are not refundable

Full Terms and Conditions

By placing an order with Ocean Controls, you agree to be bound by our Terms and Conditions of Trade.