ISEE-ModbusTCP Software

Available for backorder
Free shipping
  • SKU
    OCS-015

ISEE-ModbusTCP is an economically priced SCADA software program that can monitor and control serial Modbus and Modbus TCP slaves.

Buy more for less:
Quantity ex GST incl GST Saving
1-4 items $118.61 / each N/A  
5-9 items $106.74 / each N/A save 10%
10 or more items $100.81 / each N/A save 15%
  • $118.61
Qty:  

Our popular ISEE-Modbus software has had a major update. ISEE-MobusTCP data acquisition program is a fully-featured minimum cost HMI program for controlling and monitoring controllers, PLCs and instrumentation that use the Modbus and Modbus TCP protocol. Runs under Windows 10/8/7/Vista/XP (requires Microsoft .Net Frameworks to be installed on your PC)

ocs-015_2.jpg

Simple to configure and run, the ISEE-ModbusTCP software will allow you to monitor PLC and Controller I/O and variables and with the inbuilt control language and operator interface control setpoints and outputs. All analog I/O, digital I/O and calculated variables can be logged to a time and date stamped csv file. The csv file can be easily imported into Excel or Access for analysis or you can use our charting feature (see image below) to analyse the data. The operator can use the cursor on the charts to look at values and easily zoom in and out.

ocs-015_1.jpg


Trialing ISEE-ModbusTCP:

After downloading and installing the software you can run the software for 30 mins. You will be able to carry out all the normal functions including saving your parameters and setup. After 30 minutes a warning will appear and the program will stop operating.

Purchasing:

After downloading and installing the software you will need to register the software. Firstly run the program and then click on the registration option in the main menu and you will see a serial number that is linked to the serial number of the PC. After payment, email or phone us with the serial number and you will be issued with a registration number matching that serial number. If you wish to first develop your software on a PC and then move it to the permanent machine, you will need to send us the serial number of both PCs

Features Include:

  • Protocol: Modbus TCP, RTU and ASCII
  • Interrogate multiple controllers, PLCs and instruments
  • Write to the coils and holding registers
  • View the status of the coils and input status
  • View the holding and input registers. They can be viewed as raw readings or in engineering units.
  • Holding and Input registers can contain integers, long integers and floating point numbers
  • Supports up to 1024 tags
  • View the maximum and minimum values for each tag
  • No graphics to draw. Simply display the readings on the screens. Readings can be grouped as you like.
  • Log registers, coils, statuses and calculated variables to a csv type file
  • Display and analyse Historical logged files on graphs
  • Display registers, coils, statuses and calculated variables on graphs or trends
  • Display and control alarms
  • Has a control language consisting of If-Then-Else statements allowing calculations and control to be done.
  • The program configuration can be saved to disk
  • All analog, digital inputs and outputs and calculated variables are defined by tags with real names and real engineering units making it easy for you to understand what is going on.

New Features that have been added to our ISEE-Modbus:

  • Supports extended Modbus register addressing
  • View communications on the front screen. Shows you straight away if problems are occurring.
  • Can develop all the tags for a type of PID controller, Power Meter and then import that block of tags into the tag database each time a new controller or meter is connected to the PC.
  • Improved trending.
  • Logs to Daily, Weekly and Monthly Files.
  • Daily, Weekly and Monthly files are synchronized to start of the day. This helps if your are monitoring Power Meters and calculating power usage
  • Much better appearance and easier operation
  • New help file and user manual.

Faulty Goods and Warranty

Where such goods have been supplied we undertake to repair or replace them as quickly as possible.Prior to returning faulty items, please contact us with a description of the fault as one of our engineers might be able to assist you by resolving the issue over the phone.
A Warranty form must be filled out and returned with any goods.

Our standard warranty period is 12 months from the date of purchase unless stated otherwise.

Other warranty periods:

Labjack Products: 5 Years
Atop Products: 3 Years
MeanWell Products: 3 Years
Terracom Products: 3 Years

Warranty is subject to us being satisfied that a defect was caused by defective workmanship or materials and was not caused by or was not substantially contributed to by other factors beyond our control including incorrect installation, alterations or modifications of the product not recommended by the manufacturer.

Returns Policy

If you are dissatisfied with our goods you may return them within 14 days of the dispatch date. Contact us for an authorisation and we will refund your purchase less shipping costs and restocking fees. All returned goods MUST be in AS NEW condition including ALL PACKAGING and DOCUMENTATION / MANUALS etc.

Please note:

  • The product returned will attract a 20% restocking fee.
  • The customer must pay the delivery costs.
  • Non standard, custom made or a specially manufactured or imported products are not returnable.
  • Semiconductors, books and software are not refundable

Full Terms and Conditions

By placing an order with Ocean Controls, you agree to be bound by our Terms and Conditions of Trade.

Customers who viewed this product bought

Drop items here to shop
Product has been added to your cart