TCW220 - Ethernet DAQ Unit with Datalogging and IO Expansion

TCW220 - Ethernet DAQ Unit with Datalogging and IO Expansion

SKU: TCC-020

TCW220 is an Ethernet data logger for general data acquisition applications. It has 2 analog inputs, with 10-bit resolution and 2 discrete inputs. It utilises 1-Wire interface for up to eight 1-Wire sensors.

Teracom
  • Manufacturer: Teracom
Buy more for less:
1-4items$329.20/ each 
5-9items$296.28/ eachsave10%
10or more items$279.82/ eachsave15%
  • $329.20
Qty:  
Available for backorder

The TCW220 is an Ethernet data logger for general data acquisition applications. It has 2 analog inputs, with 10-bit resolution and 2 discrete inputs. It utilises 1-Wire interface for up to 8 Teracom 1-Wire sensors (carbon dioxide, 0/20mA, AC/DC current, temperature, humidity etc.) The Ethernet data logger also has 2 relays with normally open and normally close contacts. All monitored parameters can be logged on previous set time interval and/or on alarm condition. The memory is large enough for at least 36 days with records on every 1 minute. Log file can be periodically uploaded on dedicated server by HTTP Post.

XML/JSON file with all monitored parameters can periodically uploaded on dedicated server by HTTP Post. Like answer server can return commands for relay's control. This is a way for building SCADA system. The relays can be activated either remotely (WEB, SNMP, HTTP, MODBUS etc.) or locally from status of monitored parameters. For every parameter e-mails and SNMP traps for up to 5 recipients can be sent. Alarm alert also can be sent by HTTP Post with XML/JSON status files.

TC Monitor is easy to use Windows application for monitoring and control of TCW products. TC Monitor can collect and display data from controllers installed in different locations (sites). The collected data is stored in SQL database and can be displayed or exported in MS Excel format for further analysis. TC Monitor has a simple web interface, which enables easy and fast configuration. Monitored parameters can be 1-wire sensors, digital and analog inputs and relay outputs. The free version of TC Monitor provides 10 credits, this means up to 10 different parameters can be monitored and logged.

  • 1-Wire support for up to 8 1-wire sensors - temperature, humidity, carbon dioxide, 4-20mA, AC/DC current
  • Data logger functionality for at least 36 days
  • Log rate adjustable between 10 to 3600 seconds
  • Data can be logged on a time, on alarm or both time and alarm
  • Periodic data upload to dedicated server via HTTP Post
  • Web interface for configuration and monitoring
  • SNMP traps on alarm
  • e-mail on alarm - up to 5 email recipients
  • XML and HTTP API commands
  • Android and Apple iOS Apps
  • NTP protocol support
  • Real time clock for scheduled time/date control
  • DIN Rail mount enclosure
  • Power Supply: 10 to 32 VDC at 300 mA
  • Input: 2 digital inputs with "dry contact" and "logic level" modes
  • Input: 2 analogue inputs with 0 to 10 VDC range, 0.001 V resolution
  • Contacts: 2 relays with NO and NC 
  • Relay rating: 30 VAC, 24 VDC, 3 A
  • Dimensions: 115 Ă— 90 Ă— 40 mm
  • Operating temperature: -20 to +70 °C
    • SKU
      TCC-020
    • Weight
      0.2 kg
    • Dimensions (L x W x H)
      13 x 11 x 5 cm

Dispatch

In-stock orders are dispatched within 2 business days.

Shipping options

We deliver across Australia and internationally by any of the following methods: 

  • Australia Post Express
  • Australia Post Parcel Post
  • DHL
  • FedEx (only international)
  • Freight account. We'll email packaging dimensions when the shipment is ready to be book.

*Transit times vary depending on the shipping method and destination.

Store Pickup - Carrum Downs, Victoria, 3201

Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays. 

RETURNS

How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.

Return window 14 days from dispatch date.

Condition required Items must be unused and in original packaging, including all documentation and manuals.

Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.

Non-returnable items

  • Custom-made or specially imported products
  • Software licences (some software have trial versions available)
  • Items not in original, as-new condition


WARRANTY

How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods. 

What's covered Defects in materials and workmanship under normal use and correct installation.

What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.

Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.

Extended warranty 

  • Labjack: 5 Years
  • Atop: 5 Years
  • MeanWell: 3 Years
  • Teracom: 3 Years
  • Novus: 3 Years


Related products

Customers who viewed this product also bought