- Clearance
- Arduino
- CNC
- Communications
- Computer Products
- Controllers
- Data Acquisition
- Data Loggers
- Electrical Switches
- Electrical Terminals-Wiring
- Enclosures
- Industrial IoT
- Large Displays
- Lighting
- Modbus-Bacnet-MBus Products
- Motor Drivers & Controllers
- Motors & Accessories
- Panel Meters
- PLCs & HMIs
- Power Supplies
- Prototyping
- Relays & Relay Cards
- Security
- Sensors
- 1 Wire
- Accelerometers
- Capacitive Proximity
- Chemical
- Compass
- Current-Voltage
- Float Switches
- Flow
- Gas
- Hall Effect
- Inclinometers
- Inductive Proximity
- Length & Distance
- Light & Colour
- Limit & Foot Switches
- Liquid Level
- Load Cells
- PhotoElectric Switches
- Pressure Transducers
- Smartphone Based
- Temperature RTD and T/C
- Temperature Other
- Temperature & Humidity
- Ultrasonic
- VOC - Air Quality
- Signal Conditioners
- Software
- Test Equipment
- Timers
- Weather
Isolated Converters
Sort by:Name A - Z
5 Digit Dual 4-20mA input, Single 4-20mA output Math Function Isolated Transmitter
SKU:ALT-4405 Digit dual input math function isolated transmitter with two 4-20 mA inputs and 4-20 mA output. Functions available: A ± B, A × B, A ÷ B, |A|, √A, and A&B (re-transmission of highest or lowest input signal).
Note: this transmitter requires 8 pin DIN Rail base NTR-221.
Current Transducer 0--8A AC In, 4-20mA Out, 3 Wire 24VDC Power
SKU:WES-001DIN rail mount current transducer presents a 4 to 20 mA DC signal representing the AC current flowing through a primary conductor. 0 to 8 A primary AC current range.
Fema I3P configurable signal converter and isolator
SKU:FMB-010The I3P Signal Isolator accepts process signals (mA and Vdc), thermocouples (K, J, N, E, T, R, S, B), resistive temperature probes (Pt100, Pt500, Pt1000, Ni100, Ni1000, PTC and NTC), resistances and potentiometers. Easy configuration with configuration codes. We have a service to configure the I3P for you if you require it.
Fema I4E configurable signal converters for electrical signals
SKU:FMB-001The new I4E signal converters from Fema can be configured to measure voltage signals (AC and DC) with ranges from 0 / 50mV up to 0 / 600V, current signals (AC and DC) from 0 / 5mA up to 0 / 5A, and frequencies from power lines (up to 100Hz). The output is a standard process signal configurable to 4 / 20mA or 0 / 10Vdc and has 4 Digit display. We have a service to configure the I4E for you if you require it.
Fema I4F isolated signal converter for frequency, impulses, RPM speed and flow signals
SKU:FMB-007Fema I4F is an Isolated signal converter for frequency, impulses, RPM speed, and flow signals. Output signal in 4/20mA and 0/10Vdc. Isolated 3 ways.
Configurable to work with NPN, PNP, Pick-up, Namur, mechanical contact, reed contact, and other sensors. Dedicated input to measure frequency from AC voltage up to 600 Vac.
Accepts a wide range of frequency ranges, from 1 Hertz up to 1 MHertz, with a minimum workable signal of 100 milliHertz and resolution of 1 milliHertz.We have a service to configure the I4F for you if you require it.
Fema I4L isolated signal converter for Load Cells
SKU:FMB-003Fema I4L is an isolated signal converter for load cell signals and millivolts. Provides +5 Vdc excitation voltage to power the load cell, and ‘sense’ function to compensate for excitation voltage variations. Accepts direct connection of 1, 2, 3 or up to 4 load cells (typical 350 Ohms load cells). We have a service to configure the I4L for you if you require it.
Fema I4P isolated signal converter for Process and Temperature Signals
SKU:FMB-005Fema I4P is an Isolated signal converter for process, temperatures, resistances and potentiometers. Output signal in 4/20mA and 0/10Vdc. Isolated 3 ways. We have a service to configure the I4L for you if you require it.
FEMA 4-20mA Input Signal Converter with -10VDC to 10VDC Output
SKU:FMI-150The signal converter from FEMA has an input of 4-20mADC current. It can output -10VDC to 10VDC. Galvanic isolation between input, output and power circuits. The unit is powered by 24VDC.
Fema CCT-100 Simple Signal Isolator for Current Loops
SKU:FMB-020Current loop isolator for 4/20mA and 0/50mA current loop signals, . It is designed for industrial OEM applications. The CCT-100 instrument does not need any type of configuration, and is powered from the input signal loop.
Fema I3D Signal duplicator for process signals
SKU:FMB-012The Fema I3D accepts process signals in 4/20 mA and 0/10 Vdc, provides excitation voltage if needed. Dual 4-20mA outputs. Isolated 4 ways between power, input signal, output 1 and output 2. We have a service to configure the I3D for you if you require it.
Isolated Analog Signal Converter, Dual Output
SKU:NTB-003Slim isolated signal converter with dual output converts a single, selectable analog input signal to dual analog outputs. The input signal type and each output signal type can be configured with on-board DIP switches.
Isolated Analog Signal Converter, Single Output
SKU:NTB-001Slim isolated selectable analog input signals with selectable single analog output. It features on-board DIP switches that enable the user to select their preferred input/output signal.
NPT4 Slimline temperature transmitter
SKU:AKB-001The NTP4 is a universal temperature transmitter in a 6-mm wide slimline DIN rail mounting enclosure. The device is intended for the conversion of the measurement signal from a TC or a 2-, 3-, or 4-wire RTD into a 4-20 mA or 0(2)-10 V standard signal.
Temperature Transmitters TxIsoPack-HRT
SKU:SIG-025Head mount signal conditioner for converting RTDs, thermocouples and voltage signals into a 4-20 mA current with a superimposed HART protocol for digital communication.
Temperature Transmitters TxIsoPack-USB
SKU:SIG-010Fully isolated, head-mount 4 to 20 mA temperature transmitter with programmable input and USB port for easy configuration.
TT-600 Programmable Isolated DIN Rail Module 4-20mA
SKU:XMB-020ATT-600 is a galvanically isolated 4-20mA DIN Rail mounted Temperature transmitter. It accepts different kinds of thermocouple (T, E, J, K, N, R, S, Wre3-25), Pt1000 and PT100 RTD inputs and coverts them into an analog 4-20mA signal.
TxConfig USB Interface cable for NP620 Pressure Transmitter
SKU:SIG-011Txconfig USB programming cable with DIN43650 interface for configuring Novus NP620 pressure sensors.
TxConfig USB Interface cable for PC
SKU:SIG-008The TxConfig USB is the configuration interface to configure the whole NOVUS Smart Transmitters family such as TxRail, TxIsoRail, RHT sensors
TxConfig-M12 Configuration Cable
SKU:SIG-009USB programming cable for Novus TxMini-M12 signal conditioners.
TxIsoRail Isolated DIN Mount 0-10V Module
SKU:SIG-006Fully isolated DIN rail mount signal conditioner takes thermocouples, Pt100 sensors, 0 to 50 mV, 0 to 20 mA or 4 to 20 mA in and outputs 0 to 10 V. Programmable zero and span.
TxIsoRail Isolated DIN Mount 4-20mA Module
SKU:SIG-005Fully isolated DIN rail mount signal conditioner takes thermocouples, Pt100 sensors, 0 to 50 mV or 0 to 10 V in and outputs 4 to 20 mA. Programmable zero and span. Loop powered.