Stainless Steel Temperature Probe
High-level linear voltage output and high accuracy. Operating temperature range from 0 to +150 °C.
EOL - NOT AVAILABLE FOR BACKORDER.
The EI-1034 is intended to be connected to a LabJack for 5 V power but can be used as a stand-alone temperature sensor when connected to a voltage measuring device and a power supply in the range of 5 to 30 volts.
It uses the highest grade available of the LM34 sensor from National Semiconductor with a typical room temperature accuracy of ±0.4 °F or ±0.25 °C.
The sensor is mounted in a stainless steel sheath and features a high-level linear output of 10 mV per °F and has an operating temperature range of 0 to +300 °F (-17 to +150 °C with U3/UE9 or -12 °C to 150 °C with U12).
The probe is suitable for air and liquid applications, and can be conveniently secured into pipes, vessels and chambers by using available ¼ inch compression fittings.
Please note the cable is only rated for -20 to 80 °C and can be used up to 100 °C.
Note: When operating at voltages less than 5 Volts the maximum operating temperature is reduced, typically at 4 Volts supply the maximum temperature limit is 200 °F
Power: +4 to 35 VDC at 90 uA
Output current: 10 mA
Accuracy:
- ±0.4°F Typical Room Temperature
- ±1°F Max Room Temperature
- ±2°F Max 0°F to 230°F
- ±3°F Max -40°F to 0°F
- ±1°F Typical -50 °F to 300 °F
Output to LabJack or meter: 10 mV per °F
Sensor device in probe: LM34CAZ
Extending Low Temperature Range Diagram
Dispatch
In-stock orders are dispatched within 2 business days.
Shipping options
We deliver across Australia and internationally by any of the following methods:
- Australia Post Express
- Australia Post Parcel Post
- DHL
- FedEx (only international)
- Freight account. We'll email packaging dimensions when the shipment is ready to be book.
*Transit times vary depending on the shipping method and destination.
Store Pickup - Carrum Downs, Victoria, 3201
Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays.
RETURNS
How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.
Return window 14 days from dispatch date.
Condition required Items must be unused and in original packaging, including all documentation and manuals.
Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.
Non-returnable items
- Custom-made or specially imported products
- Software licences (some software have trial versions available)
- Items not in original, as-new condition
WARRANTY
How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods.
What's covered Defects in materials and workmanship under normal use and correct installation.
What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.
Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.
Extended warranty
- Labjack: 5 Years
- Atop: 5 Years
- MeanWell: 3 Years
- Teracom: 3 Years
- Novus: 3 Years