N2000S Servo Positioning PID Controllers with RS-485, 240 V
N2000S Servo Positioning PID Controllers with RS-485
The N2000 Universal Process Controller is a real breakthrough in versatility for holding in one single instrument all the major features required in the vast majority of industrial processes. With a sophisticated and consistent software and its advanced truly universal circuitry, the N2000 accepts configuration of both input signal and control output through the front keyboard without any internal hardware change.
Power supply for remote loop powered transmitters is standard and is a must for high-end applications.
The N2000S model is specific for applications in controlling servo motorized valves, servo actuators and dampers by means of two time proportional relays. Moreover it has an analog output that can be programmed to control or retransmit input or setpoint signals. Its universal analog input accepts most industry manufactured sensors and signals.
A Modbus RTU RS-485 connection is fitted. With a RS-485 interface you can use our ViewPID Software to help you monitor, tune and record the performance of the controller
You can use the Superview software or ISEE-Modbus Software to monitor and set parameters in the controller
Features
- Universal Input accepts thermocouples type J, K, T, N, R, S; Pt100 RTD, linear 4-20 mA, 0-50 mV, 0-5 Vdc.
- Double LED display: red for PV and green for SV.
- Dual SPST 3A/250 Vac relays and dual SPDT 5A/250 Vac relays can be individually programmed for control or alarm.
- Isolated 4-20mA output with 1500-level resolution, maximum 550 ohm load for control or PV/SV retransmission. It can also be configured for digital input or output (10 Vdc/20 mA).
- Sampling rate: 4 measurements per second.
- One digital input for dry contact with 5 programmable functions.
- Remote setpoint input for 4-20 mAdc signal (N2000). 24 Vdc/30 mA supply output for remote transmitter excitation.
- RS-485 comm with Modbus RTU protocol.
- Auto tuning PID control.
- Auto/Manual mode, bumpless transfer.
- Programmable Soft start up to 9999 seconds.
- Ramp and Soak: 7 programs of up to 7 segments each. Can be linked to create longer programs of up to 49 segments.
- Measured value resolution: 12,000 levels.
- Control output update: 250 ms.
- Up to four configurable relays, two timer alarms.
- Alarm functions: LO, HI, differential, differential LO, differential HI, sensor break and event.
- Alarm initial blocking function.
- Power: 85 to 250 Vac, 50/60 Hz
- Maximum consumption: 4 VA.
- Operating environment: 0 to 55ºC, 20 to 90%RH.
- Front panel: IP65, Polycarbonate UL94 V-2.
- Back panel: IP30, ABS+PC UL94 V-0.
- Dimensions: 48 x 96 x 92 mm.
- Panel cutout: 45.5 x 93 mm.
- Weight: 240 g (265 g with options).
Download the N2000 and N2000S Flyer
The N2000 Universal Process Controller is a real breakthrough in versatility for holding in one single instrument all the major features required in the vast majority of industrial processes. With a sophisticated and consistent software and its advanced truly universal circuitry, the N2000 accepts configuration of both input signal and control output through the front keyboard without any internal hardware change.
Power supply for remote loop powered transmitters is standard and is a must for high-end applications.
The N2000S model is specific for applications in controlling servo motorized valves, servo actuators and dampers by means of two time proportional relays. Moreover it has an analog output that can be programmed to control or retransmit input or setpoint signals. Its universal analog input accepts most industry manufactured sensors and signals.
A Modbus RTU RS-485 connection is fitted. With a RS-485 interface you can use our ViewPID Software to help you monitor, tune and record the performance of the controller
You can use the Superview software or ISEE-Modbus Software to monitor and set parameters in the controller
Features
- Universal Input accepts thermocouples type J, K, T, N, R, S; Pt100 RTD, linear 4-20 mA, 0-50 mV, 0-5 Vdc.
- Double LED display: red for PV and green for SV.
- Dual SPST 3A/250 Vac relays and dual SPDT 5A/250 Vac relays can be individually programmed for control or alarm.
- Isolated 4-20mA output with 1500-level resolution, maximum 550 ohm load for control or PV/SV retransmission. It can also be configured for digital input or output (10 Vdc/20 mA).
- Sampling rate: 4 measurements per second.
- One digital input for dry contact with 5 programmable functions.
- Remote setpoint input for 4-20 mAdc signal (N2000). 24 Vdc/30 mA supply output for remote transmitter excitation.
- RS-485 comm with Modbus RTU protocol.
- Auto tuning PID control.
- Auto/Manual mode, bumpless transfer.
- Programmable Soft start up to 9999 seconds.
- Ramp and Soak: 7 programs of up to 7 segments each. Can be linked to create longer programs of up to 49 segments.
- Measured value resolution: 12,000 levels.
- Control output update: 250 ms.
- Up to four configurable relays, two timer alarms.
- Alarm functions: LO, HI, differential, differential LO, differential HI, sensor break and event.
- Alarm initial blocking function.
- Power: 85 to 250 Vac, 50/60 Hz
- Maximum consumption: 4 VA.
- Operating environment: 0 to 55ºC, 20 to 90%RH.
- Front panel: IP65, Polycarbonate UL94 V-2.
- Back panel: IP30, ABS+PC UL94 V-0.
- Dimensions: 48 x 96 x 92 mm.
- Panel cutout: 45.5 x 93 mm.
- Weight: 240 g (265 g with options).
Download the N2000 and N2000S Flyer
Dispatch
In-stock orders are dispatched within 2 business days.
Shipping options
We deliver across Australia and internationally by any of the following methods:
- Australia Post Express
- Australia Post Parcel Post
- DHL
- FedEx (only international)
- Freight account. We'll email packaging dimensions when the shipment is ready to be book.
*Transit times vary depending on the shipping method and destination.
Store Pickup - Carrum Downs, Victoria, 3201
Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays.
RETURNS
How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.
Return window 14 days from dispatch date.
Condition required Items must be unused and in original packaging, including all documentation and manuals.
Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.
Non-returnable items
- Custom-made or specially imported products
- Software licences (some software have trial versions available)
- Items not in original, as-new condition
WARRANTY
How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods.
What's covered Defects in materials and workmanship under normal use and correct installation.
What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.
Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.
Extended warranty
- Labjack: 5 Years
- Atop: 5 Years
- MeanWell: 3 Years
- Teracom: 3 Years
- Novus: 3 Years