SWI-94 General Purpose Weight Indicator and Controller

SWI-94 General Purpose Weight Indicator and Controller

SKU: SII-080

The SWI-94 weight meter is designed for operations with load cells (strain gages) in simple industrial applications

Simex
  • Manufacturer: Simex
Buy more for less:
1-4items$303.67/ each 
5-9items$273.30/ eachsave10%
10or more items$258.12/ eachsave15%
  • $303.66
Qty:  
In stock(1 item available)

The SWI-94 weight meter is designed for operations with load cells (strain gages) in simple industrial applications. The meter is equipped with operating pushbuttons which allow tare weight setting, zero setting for empty balance and displaying of gross and net weight values. The readouts of the measured mass are presented on a 6-digit LED display. The REL / OC control outputs can adjust the level of measured signal and are controlled according to one or two threshold values. The meter's software allows performing two calibration methods: data sheet calibration or dead weight calibration. Moreover, the meter can be additionally equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The meter can be configured with the local keyboard or via the RS-485 communication port.

Features:

  • Weight meter to work with load cells in weighing and force measurement systems
  • Inputs: tensometer load cells 4-wire or 6-wire digital, 1 x digital
  • Outputs: 2 x digital (REL or OC), 1 x analogue (active or passive)
  • Data sheet or dead weight calibration
  • High protection class IP 65 (front side)
  • Signal peak value detection
  • RS-485 / Modbus RTU
  • CE approval
  • 92 × 45 mm panel cutout

Manufacturer part: SWI-94-1G33-1-3-011

    • SKU
      SII-080
    • Weight
      0.5 kg
    • Dimensions (L x W x H)
      10 x 8 x 10 cm
  • Power Supply: 19 to 50VDC (Optional: 16 to 35VAC or 85 to 260VAC/DC)
  • Power Consumption (max): 4.5VA (for 85 to 260VAC/DC and 16 to 35VAC); 4.5W (for 19 to 50VDC)
  • Communication interface: RS-485, 8N1 and 8N2, 1200 ÷ 115200 bit/s, Modbus RTU
  • Measurement Input:
    • Type: Tensometer load cells 4-wire or 6-wire, programmable sensitivity selectable up to 2 mV/V or 4 mV/V
    • Load Cells Power Supply: 4.6V ± 10% with max current around 60 mA
    • Load Cells Connections: max 4 load cells 350 Ohm
  • Programmable Digital Input: Separated, low level 0 to 1V; high level 10 to 30V (about 5.5 mA @ 24V)
  • Transducer Power Supply: 24 VDC + 5% -10% / max 100 mA
  • Digital Outputs: 
    • Two Relay Outputs or Open Collector Outputs
    • Relay Outputs (max): Current 1A, Voltage 30VDC/250VAC (cos ϕ =1)
    • Open Collector Outputs: Current 30 mA, Voltage 30VDC, Power 100 mW
  • Analog Outputs:
    • Active Current: 0/4 to 20mA (max 0 to 24mA), maximum load resistance 700Ω, 13 bit resolution
    • Passive Current: 4 to 20mA (max 2.8 to 24mA), isolated, load resistance 600Ω @24VDC, 13 bit resolution
    • Active Voltage: 0/1 to 5V, 0/2 to 10V (max 0 to 11V), minimum load resistance 2000Ω , 13 bit resolution
  • Display: LED, 6 x 13 mm, red (green - on request), brightness adjustable in 8 steps
  • Display Resolution: 10 000 d (max)
  • Operating Temperature: 0 to 50°C (standard), -20 to 50°C (option)
  • Storage temperature: -10 to 70°C (standard), -20 to 70°C (option)
  • Accessories: SP-4 or SP-6: load cell junction box
  • Case material: NORYL-GFN2S E1
  • Protection Class: IP 65 (front side), IP 65 frame for panel cut-out sealing in standard; IP 20 (case and connection clips)
  • Dimensions:
    • Panel Cut-Out: 90.5 x 43 (mm)
    • Case: 96 x 48 x 100 (mm)

Faulty Goods and Warranty

Where such goods have been supplied we undertake to repair or replace them as quickly as possible.Prior to returning faulty items, please contact us with a description of the fault as one of our engineers might be able to assist you by resolving the issue over the phone.
A Warranty form must be filled out and returned with any goods.

Our standard warranty period is 12 months from the date of purchase unless stated otherwise.

Other warranty periods:

Labjack Products: 5 Years
Atop Products: 3 Years
MeanWell Products: 3 Years
Terracom Products: 3 Years

Warranty is subject to us being satisfied that a defect was caused by defective workmanship or materials and was not caused by or was not substantially contributed to by other factors beyond our control including incorrect installation, alterations or modifications of the product not recommended by the manufacturer.

Returns Policy

If you are dissatisfied with our goods you may return them within 14 days of the dispatch date. Contact us for an authorisation and we will refund your purchase less shipping costs and restocking fees. All returned goods MUST be in AS NEW condition including ALL PACKAGING and DOCUMENTATION / MANUALS etc.

Please note:

  • The product returned will attract a 20% restocking fee.
  • The customer must pay the delivery costs.
  • Non standard, custom made or a specially manufactured or imported products are not returnable.
  • Semiconductors, books and software are not refundable

Full Terms and Conditions

By placing an order with Ocean Controls, you agree to be bound by our Terms and Conditions of Trade.

Related products

Customers who viewed this product also bought