Fema  I4F isolated signal converter for frequency, impulses, RPM speed and flow signals

Fema I4F isolated signal converter for frequency, impulses, RPM speed and flow signals

SKU: FMB-007

Fema I4F is an Isolated signal converter for frequency, impulses, RPM speed, and flow signals. Output signal in 4/20mA and 0/10Vdc. Isolated 3 ways.
Configurable to work with NPN, PNP, Pick-up, Namur, mechanical contact, reed contact, and other sensors. Dedicated input to measure frequency from AC voltage up to 600 Vac.
Accepts a wide range of frequency ranges, from 1 Hertz up to 1 MHertz, with a minimum workable signal of 100 milliHertz and resolution of 1 milliHertz. 
 

We have a service to configure the I4F for you if you require it.

Fema
Buy more for less:
1-4items$211.46/ each 
5-9items$190.32/ eachsave10%
10or more items$179.74/ eachsave15%
  • $211.46
Qty:  
In stock(6 items available)

Isolated signal converter for frequency, impulses, RPM speed, and flow signals. Output signal in 4/20mA and 0/10Vdc. Isolated 3 ways.

Configurable to work with NPN, PNP, pickup, Namur, mechanical contact, reed contact, and other sensors.

Dedicated input to measure frequency from AC voltage up to 600 Vac.

Accepts a wide range of frequency ranges, from 1 Hertz up to 1 MHertz, with a minimum workable signal of 100 milliHertz and resolution of 1 milliHertz.

Output signal configurable for 4/20 mA (active and passive) and 0/10 Vdc. Universal power supply from 18 to 265 Vac/dc. 3-way isolation between input, output, and power circuits.

Customizable input and output signal ranges. Configuration through front push-button keypad and front display. Configurable information messages (tare value, mV at terminals, input signal value, output signal value, configured label, signal percentage, process value, excitation voltage value, and excitation current value). Manual "force" functions to generate low and high output signals, to validate remote instrumentation during installation. "Tare" function. "Password" function to block unauthorized access to the configuration menu. "SOS" mode to help with critical maintenance and repairs without affecting the manufacturing process.

Designed for industrial use, with potential integration into a wide range of applications. Optional customization.



POWER SUPPLY:

  • Voltage range 18 to 265 Vac/dc isolated (20 to 240 Vac/dc ±10%) 
  • AC frequency 45 to 65 Hz 
  • Consumption <3.5 W 
  • Power wires 1 mm2 to 2.5 mm2 (AWG17 to AWG14) 
  • Overvoltage category

ISOLATION:

  • Input-output 3000 Veff (60 seconds) 
  • Power - input 3000 Veff (60 seconds) 
  • Power - output 3000 Veff (60 seconds) 

SENSORS: 

  • Types of sensor NPN, PNP, pick-up, push-pull, mechanical contact, reed contact, Vac
  • Max. voltage at terminals (see Manual Table 3)
  • Input impedance (see Manual  Table 11)
  • Maximum frequency (see Manual  Table 11)
  • Excitation voltage 15 Vdc @50 mA, 8.2 Vdc @50 mA, 5 Vdc @50 mA
  • Typical detection levels (see Manual  Table 3) 

 ACCURACY AT 25ºC: 

  • ‘Slow’ mode error f 2 x 0.5 x 10-6 Hz. 
  • ‘Fast’ mode error 1/gate (see Manual  ‘gate’ parameter at section 16.2) (typical error 2 Hz for ‘gate’ of 0.5 seconds) 
  • Quartz accuracy ±50ppm 
  • mA output accuracy 0.05 % FS Vdc
  • Output accuracy 0.10 % FS thermal drift 50 ppm/ºC
  • Min. detectable frequency 100 mHz (signals below 100 mHz are                                                                 considered 0 Hz) 
  • Resolution 1 mHz 

STEP RESPONSE: 

  • In ‘fast’ mode ‘Gate’ parameter + 50 mSec.
  • In ‘slow’ mode 1/frequency + 50 mSec. 

OUTPUT SIGNAL RANGES:

  • Active current output 4/20 mA active max. <22 mA, min.  0 mA maximum load <400 Ohm 
  • Passive current output 4/20 mA passive max. 30 Vdc on terminals
  • Voltage output 0/10 Vdc, max. <11 Vdc, min. -0.05 Vdc (typ.) minimum load > 10 KOhm 

CONFIGURATION SYSTEM:

  • Keypad + display accessible at the front of the instrument
  • Configuration ‘configuration menu’ and predefined ‘codes’ scalable units scalable input ranges 
  • Scalable output ranges scalable process display7

ENVIRONMENTAL: 

  • IP protection IP30
  • Impact protection IK06 
  • Operation temperature from 0 to +50 ºC 
  • Storage temperature from -20 to +70 ºC
  • ‘Warm-up’ time 15 minutes
  • Humidity 0 to 95% non-condensing
  • Altitude up to 2000 meters

MECHANICAL 

  • Size 106 x 108 x 22.5 mm
  • Mounting standard DIN rail (35 x 7.5 mm)
  • Connections plug-in screw terminal (pitch 5.08 mm)
  • Housing material polyamide V0
  • Weight <150 grams
  • Packaging 120 x 115 x 30 mm, cardboard
    • SKU
      FMB-007
    • Weight
      0.15 kg
    • Dimensions (L x W x H)
      12 x 12 x 3 cm

Dispatch

In-stock orders are dispatched within 2 business days.

Shipping options

We deliver across Australia and internationally by any of the following methods: 

  • Australia Post Express
  • Australia Post Parcel Post
  • DHL
  • FedEx (only international)
  • Freight account. We'll email packaging dimensions when the shipment is ready to be book.

*Transit times vary depending on the shipping method and destination.

Store Pickup - Carrum Downs, Victoria, 3201

Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays. 

RETURNS

How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.

Return window 14 days from dispatch date.

Condition required Items must be unused and in original packaging, including all documentation and manuals.

Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.

Non-returnable items

  • Custom-made or specially imported products
  • Software licences (some software have trial versions available)
  • Items not in original, as-new condition


WARRANTY

How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods. 

What's covered Defects in materials and workmanship under normal use and correct installation.

What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.

Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.

Extended warranty 

  • Labjack: 5 Years
  • Atop: 5 Years
  • MeanWell: 3 Years
  • Teracom: 3 Years
  • Novus: 3 Years


Related products

Customers who viewed this product also bought