LabJack U6 Data Acquisition Module

LabJack U6 Data Acquisition Module

SKU: LAJ-041

LabJack U6 USB IO module with 14 analog inputs (up to 16 bit resolution), 2 analog outputs and 20 digital IO.

LabJack
  • Manufacturer: LabJack
Buy more for less:
1-4items$513.11/ each 
5or more items$487.46/ eachsave5%
  • $513.11
Qty:  
In stock(2 items available)

The U6-Pro has all the features of the normal U6 with the addition of an auxiliary low-speed hi-resolution (24-bit) sigma-delta ADC. This converter takes about 125 ms per sample and provides an effective resolution of about 22-bits over the 0-5 or ±5 Volt ranges. Linearity and accuracy are also improved compared to the normal converter. 

Analog Inputs

The LabJack U6 has 14 external analog inputs (AIN0-AIN13). AIN0-AIN3 are available on screw terminals and also on the DB37 connector. All 14 analog inputs are available on the DB37 connector.

The maximum input range is ±10 volts, with software selectable gains of x1, x10, and x100. Each analog input can be measured single-ended, or differential even/odd pairs. Analog input resolution is 16 bits at max speed (~20us conversion time), increasing to 18+ bits at slower speeds (see sections 3.1 and 3.2 of manual). Input impedance is at least 1G ohm, with typical input bias currents of only 10 nA.

Command/response (software timed) analog input reads typically take 1-4 ms depending on number of channels and communication configuration. Hardware timed input streaming has a maximum rate that varies with resolution from 4 ksamples/s at 18 bits to 50 ksamples/s at 16 bits.

The U6-Pro has all the features of the normal U6 with the addition of an auxiliary low-speed high-resolution (24-bit) sigma-delta ADC. Analog input resolution varies from 19.5 bits (RMS or Effective) at max speed (4 ms conversion time), to 22 bits at slower speeds (160 ms conversion time). // For more information about the analog inputs see Section 2.7 and Appendix A of the User's Guide. For data rate information see Sections 3.1 and Sections 3.2. The User's Guide can be found on the U6 downloads page.

Temperature Sensor

The LabJack U6 has a temperature sensor located very close to the AIN0-AIN3 screw-terminals. Accuracy is ±2 degrees C (max). This sensor is particularly useful for thermocouple cold junction compensation (CJC).

Fixed Current Outputs

The LabJack U6 has 2 fixed current outputs of 10 uA and 200 uA. These are useful for measuring resistance.

Analog Outputs 

The LabJack U6 has 2 analog outputs (DAC0 and DAC1) that are available both on screw terminals and the DB37 connector. Each analog output can be set to a voltage between about 0 and 5 volts with 12-bits of resolution. The analog outputs are based on a true voltage reference. // The analog outputs are updated in command/response mode, with a typical update time of 1-4 ms depending on communication configuration.

For more information about the analog outputs see Section 2.8 and Appendix A of the User's Guide. For data rate information see Section 3.1. The User's Guide can be found on the U6 downloads page.

Digital I/O

The LabJack U6 has 20 digital I/O channels which can be individually configured as input, output-high, or output-low.

The first 4 FIO are available on screw terminals and the DB37 connector. All 8 FIO and 3 MIO are available on the DB37 connector, and 8 EIO and 4 CIO are available on the DB15 connector. Note that on the U6, CIO0-CIO2 are the same as MIO0-MIO2.

Command/response (software timed) reads/writes typically take 1-4 ms depending on communication configuration. The digital inputs can also be read in a hardware timed input stream where up to 16 inputs count as a single stream channel.

For more information about the digital I/O see Section 2.9 and Appendix A of the User's Guide. For data rate information see Sections 3.1 and 3.2. The User's Guide can be found on the U6 downloads page.

Timers 

Up to 4 digital I/O can be configured as timers. The timers are very flexible, providing options such as PWM output, pulse timing, pulse counting, and quadrature input. For more information about the timers see Section 2.10 and Appendix A of the User's Guide. The User's Guide can be found on the U6 downloads page.

Counters 

Up to 2 digital I/O can be configured as 32-bit counters. Since counting is one possible mode of the timers above, the U6 has up to 6 counting inputs. For more information about the counters see Section 2.10 and Appendix A of the User's Guide. The User's Guide can be found on the U6 downloads page.

I/O Protection

All I/O lines on the U6 are protected against minor overvoltages. The AIN lines can withstand continuous overvoltage of ±20 volts, the FIO lines can withstand up to ±10 volts, while the EIO/CIO/MIO lines can withstand up to ±6 volts. 

High Channel Count Applications 

By using USB hubs or Ethernet switches, many LabJacks can be interfaced to a single PC, providing an inexpensive solution for low-speed high channel count applications.

Satisfaction Guaranteed

Everything we sell has a 30-day money back guarantee. If, for any reason, you are not satisfied with a product, contact us to arrange your choice of a refund or replacement. In addition, the LabJack U6 is covered by a 5-year limited warranty.

Technical Support 

All LabJacks include lifetime technical support. Support resources include forum and FAQs.

For more information:

The User's Guide on U6 Support Page has all the specifics for working with the U6. You'll also find the quick start guides, software drivers and any other literature we've published on the U6.

Analog Inputs: 14 (16-18+ Bits Depending on Speed)

Analog Input Range: ±10, ±1, and ±0.1 Volts

Fixed Current Outputs: 2 (200/10 uA)

Analog Outputs: 2 (12-Bit, ~0-5 Volts)

Digital I/O: 20

  • U6-Pro Adds 24-bit Low-Speed ADC for 22-Bit Effective Resolution
  • Single-Ended Inputs (14) or Differential Inputs (7)
  • Instrumentation Amplifier Inputs
  • Up to 2 Counters (32 Bits Each)
  • Up to 4 Timers (Pulse Timing, PWM Output, Quadrature Input, ...)
  • Built-In CJC Temperature Sensor

Software Programmable Gains: x1, x10, and x100

Supports: SPI, I2C, and Asynchronous Serial Protocols (Master Only). Also Software or Hardware Timed Acquisition

Maximum Input Stream Rate: 50 kHz (Depending on Resolution)

Capable of Command/Response Time: Less Than 1 Millisecond

Interface: USB 2.0/1.1 Full Speed

Powered: by USB Cable

Rated for Industrial Temperature Range: -40 to +85 °C

Dimension: 75 x 185 x 30 mm

Built-In Screw Terminals for Some Signals 

Includes USB Cable and Screwdriver

Includes Licensed Copy of DAQFactory Express Software (Win2000+)

Examples Available for C/C++, VB, LabVIEW, Python, and More

Warranty 5 years

    • SKU
      LAJ-041
    • Weight
      0.35 kg
    • Dimensions (L x W x H)
      24 x 9 x 7 cm

Dispatch

In-stock orders are dispatched within 2 business days.

Shipping options

We deliver across Australia and internationally by any of the following methods: 

  • Australia Post Express
  • Australia Post Parcel Post
  • DHL
  • FedEx (only international)
  • Freight account. We'll email packaging dimensions when the shipment is ready to be book.

*Transit times vary depending on the shipping method and destination.

Store Pickup - Carrum Downs, Victoria, 3201

Order before 11am to collect after 2pm the same day. Mon–Fri, 9am–5pm, excludes public holidays. 

RETURNS

How to return an item Contact us before sending anything back. Email info@oceancontrols.com.au or call +61 3 9708 2390. We'll confirm eligibility and guide you to the return process.

Return window 14 days from dispatch date.

Condition required Items must be unused and in original packaging, including all documentation and manuals.

Restocking fee A 20% restocking fee applies to all accepted returns. Return shipping costs are the customer's responsibility.

Non-returnable items

  • Custom-made or specially imported products
  • Software licences (some software have trial versions available)
  • Items not in original, as-new condition


WARRANTY

How to make a warranty claim Before returning anything, please contact us. Our engineers can often resolve the issue remotely. If a return is required, our team will provide you with a warranty form to include with the goods. 

What's covered Defects in materials and workmanship under normal use and correct installation.

What's not covered The warranty does not cover damage or failures caused by factors outside our control, including incorrect installation, unauthorised alterations or modifications, or any installation or use not recommended by the manufacturer.

Standard warranty All products carry a 12-month warranty from the date of purchase unless stated otherwise.

Extended warranty 

  • Labjack: 5 Years
  • Atop: 5 Years
  • MeanWell: 3 Years
  • Teracom: 3 Years